摘要 A novel Micro-pattern gaseous detector (MPGD), thick GEM with electrodes made of a resistive material (RETGEM) is presented. In this paper we mainly investigate the energy resolution of a RETGEM in Ar+CO2 with different gas mixtures. The results indicate that an energy resolution 30% in single and double mode can be obtained. The existence of an optimum energy resolution is discussed. A novel Micro-pattern gaseous detector (MPGD), thick GEM with electrodes made of a resistive material (RETGEM) is presented. In this paper we mainly investigate the energy resolution of a RETGEM in Ar+CO2 with different gas mixtures. The results indicate that an energy resolution 30% in single and double mode can be obtained. The existence of an optimum energy resolution is discussed.
出处 《Chinese Physics C》 SCIE CAS CSCD 2010年第4期479-481,共3页 中国物理C(英文版)
基金 Supported by Knowledge Innovation Project of Chinese Academy of Sciences (KJCX1-YW-004,YFKJCX3.SYW.N5) Major State Basic Research Developing Program (2008CB817702)
关键词 RETCEM detector energy resolution Ar+CO2 single mode double mode RETCEM detector, energy resolution, Ar+CO2, single mode, double mode
  • 相关文献

参考文献3

  • 1Sauli F.Nucl.Instrum.Methods A,1997,386:531.
  • 2Chechik R,Breskin A,Shalem C et al.Nucl.Instrum.Methods A,2004,535:303.
  • 3Oliveira R,Peskova V,Pietropaolo F et al.Nucl.Instrum.Methods A,2007,576:362.