期刊文献+

基于双激光幕的弹丸初速测量系统研究 被引量:6

Research on Muzzle Velocity Measurement System Based on Dual Laser Light Screen
下载PDF
导出
摘要 弹丸初速的标称值与实际值存在着差异,此误差影响火炮的射击精度,因此有必要对弹丸的实际初速进行测定。基于双激光幕区截原理的弹丸初速测量系统,采用激光测距机和光栅尺进行距离的测量和标定,选用ARM和CPLD对测速过程进行全过程记录采集,通过平均测速法计算得到弹丸初速,对系统的测量误差进行了分析,系统样机经过实弹射击试验得到某口径弹丸的试验数据。对系统的误差分析及实弹射击证明,双激光幕测速系统在弹丸初速测量的精度和可靠性等方面有了显著的提高,可较好地进行初速的校准测量。 There are errors between the theory value and practical value of projectile muzzle velocity.The error has a certain influence on fire accuracy of the gun.So it is necessary to measure the practical value of muzzle velocity.Muzzle velocity measurement system based on dual laser light screen area intercepting theory made use of laser range finder and raster ruler to measure distance.ARM and CPLD were used to record and collect data during the whole process of muzzle velocity measurement.Muzzle velocity of projectile was calculated according to average velocity method.The measuring errors of the system were analyzed.The firing tests of system prototype were performed and testing data of some caliber projectiles were acquired.System error analysis and actual firing test results showed that by means of muzzle velocity measurement system based on dual laser light screen,the accuracy and reliability of muzzle velocity measurement system have a considerable improvement,and the system can satisfactorily adjust muzzle velocity measurement of the gun.
出处 《火炮发射与控制学报》 北大核心 2010年第1期67-70,共4页 Journal of Gun Launch & Control
关键词 信息处理技术 双激光幕 速度测量 弹丸初速 information processing dual laser light screen velocity measurement projectile muzzle velocity
  • 相关文献

参考文献6

二级参考文献8

共引文献47

同被引文献46

引证文献6

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部