期刊文献+

SF_6示踪检测大型容器的动态泄漏 被引量:9

Dynamic leakage test of a voluminous container using SF_6 gaseous tracer
下载PDF
导出
摘要 SF6示踪技术是大型容器动态密封检测的有效方法。采用SF6示踪技术检测了一个9m3大型容器在内部炸药爆炸后各密封部位的气体泄漏率。介绍了泄漏检测实施技术,采用Kr为第二示踪剂,用以指示SF6示踪剂的爆后燃烧损失。结果表明,各检测部位的气体泄漏主要发生在爆后短时间内,泄漏率随时间的延长呈指数衰减,29h后基本平衡在10–12–10–13L/h的泄漏水平;炸药爆炸冲击波是气体泄漏的主要原因,爆后密封材料和机械密封结构基本未遭到破坏。 SF6 gaseous tracer is an effective technology for airtight test of voluminous containers. In this work, with SF6 gaseous tracer, the dynamic leakage of a voluminous inter-explosion container was tested. Kr was selected to indicate the loss of SF6 caused by the explosion-caused high temperature. The results showed that the gas leakage for various airtight points occurred a short time after explosion, and attenuated rapidly with time by exponential order to the stable leavl of 10^-12-10^-13 L/h in 29 hours after the explosion. As a result, the shock wave was considered as the chief matter responsible for gas leak. The material and mechanical structures for airtightness were not damaged.
出处 《核技术》 CAS CSCD 北大核心 2010年第4期312-315,共4页 Nuclear Techniques
关键词 泄漏检测 示踪技术 气体示踪剂 SF6 Leakage test, Tracer technology, Gaseous tracer, SF6
  • 相关文献

参考文献7

二级参考文献67

  • 1[40]Vincent, A. M. , and R. J. Farber, Relating summer ambient particulate sulfur, sulfur dioxide, and light scattering to gaseous tracer emissions from the MOHAVE Power Project, J. Air & Waste Manag. Assoc. , 2000,50, 746~755.
  • 2[41]Watson, T. B. , R. Johnson, M. L. Pitchford et al, The Perfluorocarbon tracer releases during the Big Bend Regional Aerosol and Visibility Observational (BRAVO) study, http: //www. aqd.nps.gov/ard/bravo/BRAVO _ tracer. release. pdf
  • 3[42]Hales, J. M. , Tracer applications in the California Regional PM2. 5/PM10 air quality study, 1998, http://www. arb. ca. gov/airways/Documents/drafts/report. pdf
  • 4[43]Dugstad, O. , T. Bjoernstad, and I. A. Hundere, Measurements of gas tracer retention under simulated reservoir conditions, J. Pet. Sci. Eng., 1993, 10 (1), 17~25.
  • 5[44]Dietz, R. N. , Commercial applications of perfluorocarbon tracer (PFT) technology, BNL-46265, Upton, NY,Brookhaven National Laboratory, 1991.
  • 6[45]Ledwell J. R. , A. J. Watson, and W. S. Broccher, A deliberate tracer experiment in Santa Monica Basin, Nature, 1986, 323, 322~324.
  • 7[46]Watson, A. J. , M. I. Liddicoat, and J. R. Ledwell, Perfluorodecalin and sulfur hexafluoride as purposeful marine tracers: some deployment and analysis techniques, Deep-Sea Res. , 1987, 34, 19~31.
  • 8[47]Fogelqvist, E. , M. Krysell, and P. Ohman, Evaluation of perfluoromethyldecalin as a deliberate tracer for the study of water mixing process, Marine Chem. , 1989, 26, 339~349.
  • 9[48]Jin, M. , M. Delshad, V. Dwarakanath et al, Partitioning tracer test for detection, estimation and remediation performance assessment of subsurface nonaqueous phase liquids, Water Resour. Res. , 1995, 31, 1201~ 1210.
  • 10[49]Deeds, N. E. , D. C. McKinney, and G. A. Pope, Vadose zone characterization at a contaminated field site using partitioning interwell tracer technology, Environ. Sci. Technol. , 1999, 33, 2745~2751.

共引文献42

同被引文献73

引证文献9

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部