摘要 针对受毒死蜱污染的原水,通过小试研究了粉末活性炭(PAC)吸附强化聚合氯化铝混凝工艺对毒死蜱的去除效果。结果表明,单独投加8mg/L聚合氯化铝和0.05mg/LPAM难以将毒死蜱浓度降低至《生活饮用水卫生标准》的限值(0.03mg/L)要求,需要采用PAC吸附与混凝沉淀联用工艺。当原水毒死蜱浓度超标5,10,20,30,40和50倍时,所对应的粉末活性炭最佳投加量分别为20,30,30,40,40和50mg/L,出水浓度均小于0.03mg/L。PAC吸附强化工艺聚合氯化铝混凝工艺可有效应对原水的毒死蜱污染,保障供水安全。 A lab test was carried out to investigate the removal of chlorpyrifos in the raw water by using powder activated carbon (PAC) adsorption enhanced polyaluminium chloride coagulation.The results indicated that it was difficult to reduce the concentration of chlorpyrifos to the required value (0.03 mg/L)in the Standards for Drinking Water Quality by only dosing 8 mg/L polyaluminium chloride and 0.05 mg/L PAM,and combination process of PAC adsorption and coagulation sedimentation would be needed.The concentrations of chlorpyrifos in the treated water were all less than 0.03 mg/L when the concentrations of chlorpyrifos in the raw water were 5,10,20,30,40 and 50 times of the standard value with the corresponding optimal PAC dosages of 20,30,30,40,40 and 50 mg/L respectively.PAC adsorption enhanced polyaluminium chloride coagulation was an effective process for the removal of chlorpyrifos in the raw water and could ensure safe water supply.
出处 《供水技术》 2010年第2期8-11,共4页 Water Technology
基金 国家高技术研究发展计划(863)项目(2008AA06A414) 国家科技支撑计划重点项目(2006BAJ08B09)
关键词 毒死蜱 应急处理 粉末活性炭 chlorpyrifos emergency treatment PAC
  • 相关文献

参考文献6

二级参考文献12

  • 1蒋峰,范瑾初.粉末活性炭应用研究[J].中国给水排水,1995,11(5):4-8. 被引量:29
  • 2张小平.合肥巢湖水投加粉末活性炭除臭[J].中南给水排水,1992,(3):28-29.
  • 3[1]Koch B. Control of 2-methylisoborneol and geosmin by ozone and peroxone: a pilot study [J]. Wat Sci Tech,1992,25(2) :291 -298.
  • 4E C Devitt, F Ducellier, P Cote, et al. Effects of natural organic matter causing matter and the raw water matrix on the rejection of atrzine by pressure-driven membrane. War Res, 1998, 32(9): 2563--2568
  • 5Michael R Collins, Gary L Amy, Cornellus Steelink. Molecular weight distribution, carboxylic acidity and humic substances content of aquatic organic matter. Implication for removal during water treatment . Envir Sci Technol, 1986, 20(10): 1028~1032
  • 6James A Davis, Roll Gloor. Adsorption of dissolved organic in lake water by aluminum oxide: effect of molecular weight. Envir Sci Technol, 1981, 15(10): 1223-1229
  • 7王荣昌.[D].上海:同济大学,1997.
  • 8[美]韦伯(W·J· Weber) 著,上海市政工程设计院.水质控制物理化学方法[M]中国建筑工业出版社,1980.
  • 9[加拿大]斯尼茨尔(M·Schnitzer),[加拿大]汉(S·U·Khan) 著,吴奇虎等.环境中的腐植物质[M]化学工业出版社,1979.
  • 10曹达文,张小满,李景华.粉末活性炭在水体中强制分散及其作用研究[J].中国给水排水,1997,13(6):18-21. 被引量:5

共引文献98

同被引文献30

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部