摘要
目的:通过比较研究,确定酶标仪单双波长哪个更适于生物制品活性测定实验。方法:样品通过多次实验单双波长扫描,比较得到的实验结果,进行统计分析。结果:选用双波长可以排除其他因素对结果的影响,实验结果的标准差和离散系数均较低。结论:单双波长法更适于生物活性测定实验,提高结果的准确度。
Objective:To choose a suitble method of bioactivity detection by making a contrast research,either microplate reader single wavelength or dual wavelength. Methods:Make many experiments of single wavelength and dual wavelength,compared all results,then analyzed statistically. Results:Choose dual wavelength detection,suitable for bioactivity detection,less SD and CV%. Conclusion:Single and dual wavelength are more accuracy and reduce interference factors.
出处
《中国医药导报》
CAS
2010年第11期52-53,共2页
China Medical Herald
关键词
酶标仪
单波长
双波长
Microplate reader
Single wavelength
Dual wavelength