期刊文献+

动态血糖监测系统联合胰岛素泵治疗难治性或脆性糖尿病疗效观察 被引量:8

Continuous Glucose Monitoring System Combined with Insulin Pump Treatment on Refractory or Fragile Diabetes Mellitus
下载PDF
导出
摘要 目的观察动态血糖监测系统(CGMS)与胰岛素泵联合治疗难治性或脆性糖尿病的疗效。方法采用CGMS监测17例难治性糖尿病及7例脆性糖尿病患者血糖,监测第2天开始佩带胰岛素泵治疗。结果治疗第3天与治疗前比较,难治性糖尿病及脆性糖尿病患者正常血糖比例显著增加,低血糖、高血糖比例显著降低(P<0.05)。结论CGMS与胰岛素泵联合治疗能更加安全、有效地控制血糖。 Objective To observe the effect of continuous glucose monitoring system(CGMS) combined with insulin pump treatment on refractory or fragile diabetes mellitus. Methods To monitor glucose concentration of 17 patients with refractory diabetes mellitus and 7 patients with fragile diabetes mellitus by CGMS, and begin to treat these patients with insulin pump from the 2rid day of monitoring. Results Compared with pretherapy, the rate of euglycemia in- creased, and that of hypoglycemia and hyperglycemia decreased significantly after three-day treatment(P〈0.05). Conclusion CGMS combined with insulin pump treatment can control blood glucose more safely and efficiently.
作者 姚茂篪
出处 《湖北民族学院学报(医学版)》 2010年第1期20-21,共2页 Journal of Hubei Minzu University(Medical Edition)
关键词 连续动态血糖监测 胰岛素泵 糖尿病 continuous glucose monitoring insupin pump diabetes mellitus
  • 相关文献

参考文献4

二级参考文献9

  • 1刘新民.实用内分泌学[M].北京:人民军医出版社,1998.368.
  • 2Gross TM, Bode BW, Einhorn D, et al. Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol Ther,2000,2:49-56.
  • 3Mastrototaro J. The MiniMed continuous glucose monitoring system(CGMS). J Pediatr Endocriol Metab, 1999,12:751-758.
  • 4Bode BW, Gross TM, Thornton KR, et al. Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin. Diabetes Res Clin Pract, 1999,46:183-190.
  • 5Boyne MS, Silver DM, Kaplan J, et al. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes, 2003, 52:2790-2794.
  • 6Steil GM, Rebrin K, Mastrototaro J, et al. Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor. Diabetes Technol Ther,2003,5:27-31.
  • 7Kaufman FR, Carpenter S, Gibson LC, et al. A pilot study of the continuous glucose monitoring system. Diabetes Care, 2001,24:2030-2034.
  • 8Rohlfing CL, England JD, Wiedmeyer HM, et al. Defining the relationship between plasma glucose and HbA1c. Diabetes Care, 2002,25:275-278.
  • 9王岩,薛凌.胰岛素泵的临床应用及体会[J].中华临床医药杂志(北京),2003,4(4):53-53. 被引量:2

共引文献90

同被引文献63

引证文献8

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部