摘要 Dependence of the current-voltage characteristics of a non-transferred DC cascaded plasma torch used for nanoparticle synthesis, on the plasma current and the plasma argon gas flow rate are reported in this paper. The potential structure inside the torch and its dependence on the plasma current and gas flow rate are also investigated. The arc voltage is seen to exhibit negative characteristic for a current below 150 A and positive characteristic above that current value. The voltage drop near the electrodes is found to decrease with the increase in plasma current. 25~ of the total voltage is dropped near the cathode at a plasma current of 50 A and a argon plasma gas flow rate of 10 liter per minute (LPM), and it decreases to 12% with the current increasing to 300 A, and to 17% with a gas flow rate of 25 LPM. The variation in the torch efficiency with the gas flow rate and plasma current is also reported. The efficiency of the torch is found to be between 36% and 48%. In addition, the plasma gas temperature at various positions of the reactor and for different currents and voltages are measured by calorimetric estimation with a heat balance technique. Dependence of the current-voltage characteristics of a non-transferred DC cascaded plasma torch used for nanoparticle synthesis, on the plasma current and the plasma argon gas flow rate are reported in this paper. The potential structure inside the torch and its dependence on the plasma current and gas flow rate are also investigated. The arc voltage is seen to exhibit negative characteristic for a current below 150 A and positive characteristic above that current value. The voltage drop near the electrodes is found to decrease with the increase in plasma current. 25~ of the total voltage is dropped near the cathode at a plasma current of 50 A and a argon plasma gas flow rate of 10 liter per minute (LPM), and it decreases to 12% with the current increasing to 300 A, and to 17% with a gas flow rate of 25 LPM. The variation in the torch efficiency with the gas flow rate and plasma current is also reported. The efficiency of the torch is found to be between 36% and 48%. In addition, the plasma gas temperature at various positions of the reactor and for different currents and voltages are measured by calorimetric estimation with a heat balance technique.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第2期181-187,共7页 等离子体科学和技术(英文版)
关键词 DC plasma torch current voltage characteristics thermal efficiency temper- ature measurements DC plasma torch, current voltage characteristics, thermal efficiency, temper- ature measurements
  • 相关文献

参考文献22

  • 1Rao N, Girshick S, Heberlein J, et al. 1995, Plasma Chem. Plasma Process, 15:581.
  • 2Oh S M, Ishigaki T. 2004, Thin Solid Films, 457:186.
  • 3Turino M A. 2004, Sensors and Actuators B, 100:177.
  • 4Kakati M, Bora B, Sarma S, et al. 2008, Vacuum, 82: 833.
  • 5Kakati M, Bora B, Deshpande U P, et al. 2009, Thin Solid Films, 518:84.
  • 6Groot B de, Ahmad Z, Dahiya R P, et al. 2003, Fusion Engineering and Design, 66-68:413.
  • 7Oever P J van den, Helden J H van, et al. 2005, J. Appl. Phys., 98:93301.
  • 8Joachim H. 1999, Annals of the New York Academy of Sciences, 891:14.
  • 9Marotta A. 1994, Journal of Engineering Physics and Thermophysics, 66:302.
  • 10Gao Y, Munz R J, Tsantrizos P G. 1994, Plasma Chem. and Plasma Process, 14:73.