运用恒电量技术对冷却水系统的腐蚀进行监测,通过RP、Rf、Cf等电化学参数的分析,能够随时报道水处理各阶段的腐蚀变化,尤其是能够灵敏地反映出预膜膜层生长情况。
Abstract The cooling water systems were monitored by a coulostatic perturbation meter and a microcomputer as online measurement system. Based on the analysis of ET attenuation curves, relevant parameters in equirvalent circuit for the system were obtained. The corrosion thus could be reported dynamically.
出处
《材料保护》
CAS
CSCD
北大核心
1998年第11期25-27,共3页
Materials Protection