期刊文献+

化学混凝法处理酸洗磷化综合废水的研究 被引量:4

Treatment of acid-washing phosphatizing wastewater by chemical coagulation method
下载PDF
导出
摘要 为了确定适用于酸洗磷化废水的混凝剂及相应的最佳操作条件,以COD为主要考察指标,进行了一系列混凝试验。结果表明,在所选取的混凝剂中,氯化亚铁对试验原水的混凝效果最好,进一步试验确定的最佳操作条件为:氯化亚铁投加量为200mg/L,pH值为7.0,快速搅拌(搅拌强度300r/min)1min,慢速搅拌(搅拌强度90r/min)15min,沉降1h,此时,废水中COD的去除率可以达到40%。 In order to find a proper coagulant for acid-washing phosphatizing wastewater treatment and determine its optimal operation condition, a series of coagulation tests with COD as the main investigation index were carried out. The results showed that, ferrous chloride has the best coagulation performance compared with the other seclected coagulants, the optimal operation condition was determined as follows: the dosage of ferrous chloride was 200 mg/L, the pH value was 7.0, the high speed agitation(agitation intensity was 300 r/min) time was 1 minutes, the low speed agitation (agitation intensity was 90 r/min) time was 15 minutes, and the sedimentation time was 1 h. Under the above condition, the COD removal rate could reach 40%.
出处 《工业用水与废水》 CAS 2010年第2期26-28,共3页 Industrial Water & Wastewater
基金 国家自然科学基金资助项目(50808128) 国家水体污染控制与治理科技重大专项(2008ZX07314)
关键词 酸洗磷化废水 化学混凝 氯化亚铁 acid-washing phosphatizing wastewater chemical coagulation ferrous chloride
  • 相关文献

参考文献7

二级参考文献35

共引文献91

同被引文献35

引证文献4

二级引证文献5