摘要 在总结国内外冷却塔淋水填料性能测试装置的基础上,搭建了一套填料性能测试试验系统。该系统与上海理工大学HVAC人工环境系统的空气处理系统等有机结合,是HVAC综合实验室系统的一部分。通过试验,利用最小二乘法拟合出了淋水填料的性能公式,并研究了配水均匀性对冷却温差的影响。研究得到的性能规律对该种淋水填料在实际塔中的应用具有重要的指导意义。 Based on the summarization of the equipments for the performance testing of cooling tower packing in China and abroad, an experimental platform for packing performance testing was put up. The said system was combined with the air handling system of the intelligent environmental system of HVAC laboratroy in University of Shanghai for Science and Technology, and was part of HVAC comprehensive laboratory. In the test, the formula of the cooling tower packing performance was deduced with least square method, and the influence of water distribution uniformity on temperatrue difference of cooling system was studied at the same time. The performance regulation concluded through the test would have great guiding significance for the actual application of the said cooling tower packing.
出处 《工业用水与废水》 CAS 2010年第2期65-68,共4页 Industrial Water & Wastewater
基金 上海市教委重点学科建设项目资助(J50502)
关键词 冷却塔 淋水填料 性能 cooling tower packing performance
  • 相关文献

参考文献6

  • 1赵振国.冷却塔[M].北京:中国水利水电出版社,1996..
  • 2杨强生,袁仲文,朱士逖,张维竞,金深洋.冷却塔填料性能试验台和数据处理软件的开发[J].工业用水与废水,2006,37(S1):25-28. 被引量:6
  • 3GB/T1236-2000 工业通风机-用标准化风道进行性能试验[S].2001.
  • 4GB/T7725-2004.房间空气调节器[S].[S].,..
  • 5JB/T4283--1991,风机盘管机组[S].
  • 6DL/T933--2005,冷却塔淋水填料、除水器、喷溅装置性能试验方法[S].

二级参考文献1

  • 1DL/T 933-2005.冷却塔淋水填料、除水器、喷溅装置性能试验方法[S],2005.