期刊文献+

利用三次样条差值法抑制脉搏波基线漂移 被引量:9

Removal of Pulse Waveform Baseline Drift Using Cubic Spline Interpolation
下载PDF
导出
摘要 目的脉搏波检测过程中,必须克服由于呼吸运动和身体移位会导致脉搏信号的基线漂移。本文提出一种基于三次样条差值的脉搏波基线漂移抑制方法。方法选择脉搏波的各个起始点为给定点,根据各个给定点的数值利用三次样条插值拟合出基线。然后用脉搏波在各个采样时间点上的采样值减去对应时间点上的基线函数数值,得到去基线的脉搏波波形。结果通过实际测量实验表明,脉搏波去基线后,基线比较平稳,波形比较稳定。结论三次样条差值法能有效抑制脉搏波的基线漂移,并且能够很好地应用在脉搏波实时检测中。 Objective Baseline drift of pulse waveform caused by breathing and physical movement needs to be removed in pulse wave detection process. This paper presents a removal method of pulse waveform baseline drift using cubic spline interpolation. Methods Starting points of pulse waveform are selected to be the spline interpolation point. And cubic spline interpolation according to the starting points is used to fit the baseline drift. Subsequently, pulse waveform of baseline drift removed is obtained by pulse wave data minus the corresponding baseline drift values. Results The actual measurement results show that pulse waveform after removing baseline drift shows a stable baseline drift and a stable waveform. Conclusion The method of cubic spline interpolation can inhibit the baseline drift effectively. The method and can be well applied in real-time detection of pulse wave.
出处 《北京生物医学工程》 2010年第2期198-200,共3页 Beijing Biomedical Engineering
基金 北京市科技计划项目(Z0005190042011)资助
关键词 脉搏波 基线漂移 三次样条差值 pulse wave baseline drift cubic spline interpolation
  • 相关文献

参考文献7

  • 1罗志昌,张松,杨文鸣,杨子彬.脉搏波波形特征信息的研究[J].北京工业大学学报,1996,22(1):71-79. 被引量:119
  • 2Li C,Zhai J,Barreto A.Signal Processing Quantification of Changes in the Blood Volume Pulse (BVP) Waveform due to Exercise.Cancun,Mexico:Proceedings of the 25th Annual International Conference of the IEEE EMBS,2003,9:3180-3183.
  • 3Kim BS,Yoo SK.Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis.IEEE Transactions on Biomedical Engineering,2006,53(3):566-568.
  • 4Sommo L.Time varying filtering for removal of baseline wander in exercise ECGs//Computers in Cardiology.Dallas,US:IEEE Computer Society Press,1991:145-148.
  • 5张虹,孙卫新,金捷.脉搏血氧饱和度检测中自适应滤波消除运动伪差的方法研究[J].生物医学工程与临床,2001,5(1):6-8. 被引量:6
  • 6De Meersman RE,Zion AS,Teitelbaum S,et al.Deriving Respiration from Pulse Wave:A New Signal Processing Technique.American Journal of Physiology,1996,39(5):H1672-H1675.
  • 7王鹏,魏守水,黄青华.基于小波变换的自适应滤波器消除脉搏波基线漂移[J].中国医学物理学杂志,2004,21(5):296-299. 被引量:22

二级参考文献22

  • 1孙卫新,金捷,汪家旺,杨新平,陈健.脉搏血氧仪的研制和定标方法探讨[J].西安医科大学学报,1995,16(2):218-221. 被引量:9
  • 2魏守水,韩庚祥,金伟.基于金氏脉学的新型脉诊仪的研究[J].电子测量与仪器学报,2005,19(5):90-94. 被引量:11
  • 3Fabio B, Arthor JM, Edward LT. Cubic spline baseline estimation in ambulatory ECG recordings for the measurement of ST segment displacements [J]. Annual International Conferece of the IEEE Engineering in Medicine and Biology Society, 1991,3(2):584~588.
  • 4ZHENG Xiao-lin, WANG Zhi-gang, WU Nan, et al. Restraining respiratory baseline drift of impendance cardiogram signals wavelet transform[J]. Journal of Chongqing University(Natural science edition), 1997,20(5):58~62.
  • 5Park KL, Lee KJ, Yoon HR. Application of a wavelet adaptive filter to minimize distortion of ST-segme[J].Med. Biol.Eng. Copmput,1998,36(5):581-586.
  • 6Nitish V., Thakor, ZHU Yi-sheng. Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection [J]. IEEE Transactions on Biol. Eng., 1991,38(8):785-794.
  • 7A. Ahlstrom and W.J. Tompkins. Digital filter for real-time ECG signal processing sing microprocessors[J]. IEEE.Trans. Biomed. Eng.,1985,32:708-713.
  • 8Sornmo L. Time-varying filtering for removal of baseline wander in exercise ECGs [R]. In Computers in Cardiology, IEEE Computer Society Press, 1991.145-148.
  • 9张镜人,中国生物医学工程学报,1987年,6卷,3期,168页
  • 10柳兆荣,中国生物医学工程学报,1986年,5卷,2期,89页

共引文献143

同被引文献59

引证文献9

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部