通过锅炉燃烧调整试验,标定了二次风量、O2含量和排烟温度,进行了SOFA摆角调整对汽温偏差影响的试验,给出了SOFA风水平摆角优化运行的推荐参数。
Based on the boiler combustion adjustment experiment,the second air flow,the O2 content and the flue gas temperature were calibrated and verified.The influence of the SOFA swing angle adjustment on the steam temperature deviation was tested,and the optimized operation parameters of horizontal swing angle of SOFA were recommended.
出处
《华电技术》
CAS
2010年第4期8-11,共4页
HUADIAN TECHNOLOGY
关键词
超临界锅炉
燃烧调整
汽温偏差
SOFA摆角
优化
supercritical boiler
combustion adjustment
steam temperature deviation
swing angle of separated over-fired air(SOFA)