期刊文献+

XH1型自锁托槽的静及动摩擦力实验研究 被引量:2

An experimental study on static and dynamic friction of XH1-type self-ligating bracket
下载PDF
导出
摘要 背景:课题设计研发的XH1型自锁托槽是一种新型的直丝弓固定矫治器,目前国内临床上应用的自锁托槽绝大多数是进口的,具有摩擦力低、疗程短、临床操作简便快捷等优点,但其成本非常昂贵,鉴于此自主研发了此托槽。目的:对XH1型自锁托槽槽沟进行扫描电镜观察,并对其托槽行能谱分析,与其他托槽相比较,测试其静、动摩擦力的大小。方法:实验采用4种右上尖牙托槽,即XH1型自锁托槽、2E1托槽、TP直丝弓托槽及AO自锁托槽,将托槽与弓丝分别组合后在XF-1型摩擦力测试仪上进行测试,记录Fluke190型示波器标记出的摩擦力mV-ms变化规律。运用Matlab2007编译软件对图形进行细化处理以去除异常数据,取出最大静摩擦力及动摩擦力时所对应的电压值,并转换为力值,进行统计分析。结果与结论:托槽不同静、动摩擦力不同。TP托槽静、动摩擦力较大,XH1托槽静、动摩擦力较小。2E1托槽与TP托槽无差别,AO托槽与XH1托槽无差别。结果提示,自主研发的XH1型自锁托槽静、动摩擦力小,自锁方式操作简单,成本较进口自锁托槽低,临床上可以进一步推广应用。 BACKGROUND:XH1 type self-ligating bracket is a novel appliance of straight wire appliance.Currently,the majority of clinically applied self-ligating brackets are imported,which has low friction,short course of treatment,simple and efficient clinical practice.However,its cost is also very high.Therefore,we designed and developed the bracket.OBJECTIVE:Through the scanning electron microscopy(SEM) observation of XH1-type self-ligating bracket grooves,to perform the energy spectrum analysis of bracket,compare with the other bracket,and test the static and dynamic friction of this bracket.METHODS:A total of 4 kinds of upper right canine brackets,XH1-type self-ligating brackets,2E1 brackets(Shanghai),TP Straight Wire Bracket(USA),and AO self-ligating bracket(USA) were used.Brackets and arch wire were combined,respectively and tested on the XF-1-type friction tester.The friction mv-ms change marked and saved by Fluke190-type oscilloscope was recorded.The compile software graphics Matlab2007 was used to smooth the graph to remove abnormal data.The maximum static friction and a corresponding voltage(mV) value dynamic friction were obtained,and converted into force values,followed by statistical analysis.RESULTS AND CONCLUSION:Different brackets had different static and dynamic frictions.The static and dynamic friction TP-type bracket was higher than XH1-type bracket's.There was no difference between 2E1 and TP bracket,AO and XH1 bracket.This XH1-type self-ligating brackets is a self-developed product,with small static and dynamic friction,simple sterilization,and low cost,which allow widely clinical application.
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2010年第9期1567-1571,共5页 Journal of Clinical Rehabilitative Tissue Engineering Research
基金 黑龙江省攻关项目医药卫生技术领域基金资助 课题名称"仿真模拟正畸矫治过程中托槽与弓丝间摩擦力的研究"~~
  • 相关文献

参考文献19

  • 1Thorstenson GA,Kusy RP.Effects of ligation type and method on the resistance to sliding of novel orthodontic brackets with second-order angulation in the dry and wet states.Angle Orthod.2003;73:418-430.
  • 2Baccetti T,Franchi L.Friction produced by types of elastomeric ligatures in treatment mechanics with the preadjusted appliance.Angle Orthod.2006;76:211-216.
  • 3Franchi L,Baccetti T.Forces released during alignment with a preadjusted appliance with different types of elastomeric ligatures.Am J Orthod Dentofacial Orthop.2006;129:687-690.
  • 4Turnbull NR,Birnie DJ.Treatment efficiency of conventional vs self-ligating brackets:effects of archwire size and material.Am J Orthod Dentofacial Orthop.2007;131:395-399.
  • 5Harradine NW.Self-ligating brackets and treatment efficiency.Clin Orthod Res.2001;4:220-227.
  • 6Tecco S,Festa F,Caputi S,et al.Friction of conventional and self-ligating brackets using a 10 bracket model.Angle Orthod.2005;75:1041-1045.
  • 7Harradine NW.Self-ligating brackets and treatment efficiency.Clin Orthod Res.2001;4(4):220-227.
  • 8Harradine NW,Birnie DJ.The clinical use of Activa self-liga2ting brackets.Am J Orthod Dentofacial Orthop.1996;109(3):319-328.
  • 9Eberting JJ,Straja SR,Tuncay OC,Treatment time,outcome,and patient satisfaction comparisons of Damon and conventionalbrackets.Clin Orthod Res.2001;4(4):228-234.
  • 10Pizzoni L,Ravnholt G,Melsen B.Frictional forces related to self-ligating brackets.Eur J Orthod.1998;20(3):283-291.

二级参考文献22

  • 1Loftus BP, Artun J, Nicholls Jl, et al. Evaluation, of friction during sliding tooth movement in variou bracket - arch wire combinations [ J ]. Am J Orthod Dentofacial Orthop, 1999,116(3) :336-45
  • 2Braun S, Bluestein M, Moore BK, et al. Friction in perspective[J]. Am J Orthod Dentofacial Orthop, 1999,115 (6) :619-27
  • 3Ogata RH, Nanda RS, Duncanson MG Jr, et al. Frictional resistance in stainless steel bracket - wire combinations with effects of vertical deflections [ J ]. Am J Orthod Dentofacial Orthop, 1996,109 (5) :535-42
  • 4Cacclafesta V, sfonclrinl MF, Ricciardl, et al. Evaluation of friction of stainless steel and esthetic self - ligating brackets in various bracket - archwire combinations [ J]. Am J Orthod Dentofacial Orthop,2003,124 : 395 402
  • 5Adrerew LF,The straight wire appliance[J].Clin,Orthod,1976,10(10):99
  • 6Mclaughlin R P,Bennett J C.The transition form standard edgewise to preadjusted appliance systems[J].Clin.orthod.1989,23(2):142
  • 7曾祥龙,许天民.系统化正畸治疗技[M].天津:天津科技翻译出版公司,2002,13-21
  • 8Moore M M,Harrington E,Rock W P.Factors affecting friction in the pre-adjusted appliance[J].European Journal of Orthodontics,2004,26(6):579-583
  • 9Hemingway R,Williams R L,Hunt J A,et al.The influence of bracket type on the force delivery of Ni-Ti archwires[J].The European Journal of Orthodontics,2001,23(3):233-241
  • 10Michelberger DJ,Eadie RL.The friction and wear patterns of orthodontic brackets and archwi res in the dry state[J].Am J Orthod Dentofac,2000,118(5):662-674

共引文献2

同被引文献22

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部