超声图像预处理方法的改进研究 被引量:3

Study on the improvement of the pre-processing of the medical ultrasound image
下载PDF
导出
摘要 目的在对超声图像传统预处理方法进行处理后效果对比分析的基础上,提出一些改进措施。方法以超声医学影像为关键点,分析其噪声,提取噪声特征,从空间域处理技术来阐述超声医学影像的预处理方法。结果生物医学图像预处理技术是医学图像系统中最关键的技术之一,直接影响医生的正确诊断,以及后期的医学数据分析。对原始图像经过双精度处理,图像整体亮度会被拉低。变换图像窗口,选择感兴趣的灰度区域进行灰度提升,增强图像的灰度可视信息,对比未做双精度处理前的实验。结论采用新的灰度处理方法后的图像,具有平滑的边缘,清晰的细节,能更好地保留细节信息,具有一定的现实意义和实用价值。 Objective To explore some measures to improve the traditional pre-processing method of ultrasound medical image,and the effect was analysed. Methods To analyze the noise and the characteristics in the ultrasound medical image,and describe the ultrasound medical imaging pre processing methods in terms of the space do- main. Results The biomedical image pre-processing technology is the most critical one in medical image systems, which has an impact on the doctor's diagnosis and medical data analysis. The whole image brightness reduced after the double-precision processing. By the way of changing the window of the ultrasound medical image, lifting the grayscale of interest regions,enhancing image grayscale visibility and comparing the experiment via the double-precision processing with the experiment without double-precision processing. Conclusion The experiment results show that the ultrasound medical image processed by the new gray processing method has the smooth edges, high definition detail and reserves the detail image information better. It has some practical significance and feasibility.
出处 《检验医学与临床》 CAS 2010年第8期686-688,共3页 Laboratory Medicine and Clinic
关键词 超声影像 噪声抑制 图像增强 直方图 ultrasonic image noise suppression control image enhancement histogram
  • 相关文献

参考文献5

共引文献7

同被引文献24

  • 1关新平,赵立兴,唐英干.图像去噪混合滤波方法[J].中国图象图形学报(A辑),2005,10(3):332-337. 被引量:110
  • 2郭敏,马远良,朱霆.基于小波变换的医学超声图像去噪及增强方法[J].中国医学影像技术,2006,22(9):1435-1437. 被引量:28
  • 3吴亚东,孙世新,张红英,韩永国,陈波.一种基于图割的全变差图像去噪算法[J].电子学报,2007,35(2):265-268. 被引量:9
  • 4赵于前,柳建新,刘剑.基于形态学重构运算的医学图像分割[J].计算机工程与应用,2007,43(10):238-240. 被引量:20
  • 5Dan S,Li X Y, Liu D C.Optimized GPU framework for speckle reduction using histogram matching and region growing[C].4th International Conference on Bioinformatics and Biomedical Engineering,2010.
  • 6Guo Y H,Cheng H D,Tian J W, et al.A novel approach to speckle reduction in ultrasound imaging [J].Ultrasound in Medicine and Biology,2009,35(4):628.
  • 7Liu H J,Liu D C.Tissue flow detection based on fuzzy logic processing[C].3rd International Conference on Bioinformatics and Biomedical Engineering,2009.
  • 8Biglarbegian M,Melek W W, Mendel J M.On the stability of interval type-2 TSK fuzzy logic control systems [J].IEEE Transactions on Man and Cybernetics,Part B:Cybemetics,2010,40(3): 798-818.
  • 9David B,Jensen J A.Modeling transducer impulse responses for predicting calibrated pressure pulses with the ultrasound simulation program Field II [J]. J Acoust Soc Am, 2010,127 (5): 2825-2835.
  • 10Jensen J A. Simulation of advanced ultrasound systems using field II[C].IEEE International Symposium on Biomedical Imaging:Nano to Macro,2004:636-639.

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部