期刊文献+

光路追迹法计算角膜屈光手术后人工晶状体的屈光力 被引量:3

Calculation of intraocular lens power after corneal refractive surgery using ray tracing method
下载PDF
导出
摘要 目的建立光路追迹法计算人工晶状体屈光力的方法,探讨其对角膜屈光手术后人工晶状体屈光力计算的准确性。方法根据眼屈光间质的特点以专业光学设计软件Zemax建立人工晶状体眼模型。对25例角膜屈光手术后白内障患者进行回顾性研究,以OrbscanⅡz或C-Scan测量角膜地形图,获得角膜前表面曲率,以IOL-Master测量眼轴长度。将所得参数及人工晶状体的参数输入光学设计软件Zemax,建立人工晶状体眼的光学模型,计算白内障手术后眼的屈光状态。以手术实际屈光状态为标准,计算二者间的差异为预测误差及预测误差的绝对值为绝对预测误差。统计学分析预测误差与绝对预测误差的平均值、标准差及分布。结果光路追迹法的预测误差为-1.09~1.91 D,平均预测误差为(0.28±0.73)D;绝对预测误差为0.01~1.91 D,平均绝对预测误差为(0.63±0.45)D。绝对预测误差≤0.5 D者9例(36%),0.5 D<绝对预测误差≤1.0 D者12例(48%),1.0 D<绝对预测误差≤1.5 D者3例(12%),1.5 D<绝对预测误差≤2.0 D者1例(4%),绝对预测误差≤1.0 D者21例(84%)。结论光路追迹法是以人工晶状体眼为光学模型计算人工晶状体的屈光力,可对计算角膜屈光手术后人工晶状体屈光力进行较为准确的计算。 Background The calculation of intraocular lens(IOL) power is important for cataract patient following corneal refractive surgery.Theoretically,ray tracing for intraocular lens calculation is an ideal method because pseudophakic optics can be imitated by this method.ObjectiveThis study is to introduce ray tracing method for IOL power calculation after corneal refractive surgery and evaluate the accuracy of ray tracing method.MethodsPseudophakic eye models to perform ray tracing calculations were constructed using optical software Zemax(Zemax-EE Optical Design Program,Focus Software,Inc.USA) by importing the corneal and IOL radii,refractive indexes of cornea,aqueous,IOL and vitreous.Ten eyes of Chinese patients and 15 eyes of German patients undergone corneal refractive surgery were enrolled in this study.Corneal radius was measured by Orbscan Ⅱ z or C-Scan.Axial length was measured by IOL Master or A-scan.The refraction after cataract surgery was predicted by ray tracing method.The difference between actual postoperative refraction and predicted refraction was defined as prediction error,and absolute value of prediction error was defined as absolute prediction error.The mean value,standard deviation and distribution of both prediction error and absolute prediction error were calculated using SPSS11.0 software.ResultsA pseudophakic eye model for IOL power calculation was constructed in this study.Mean prediction error was 0.28±0.73 diopter(D)(range-1.09 D to 1.91 D);mean absolute prediction error was 0.63±0.45 D(range 0.01 D to 1.91 D).For absolute prediction error,9 eyes(36%) were confined within 0.5 D;12 eyes(48%) were confined between 0.5 D and 1.0 D;3 eyes(12%) were confined between 1.0 D and 1.5 D;1 eye(4%) was confined between 1.5 D and 2.0 D.Totally 21 eyes(84%) were confined within 1.0 D.ConclusionRay tracing method is a reliable method for the calculation of intraocular lens power after corneal refractive surgery.
出处 《眼科研究》 CSCD 北大核心 2010年第4期356-359,共4页 Chinese Ophthalmic Research
基金 广东省医学科研基金(A2005040) 广州市科技计划项目(2006Z3-E0321)资助
关键词 光路追迹 人工晶状体 屈光力计算 角膜屈光手术 ray tracing method intraocular lens power calculation corneal refractive surgery
  • 相关文献

参考文献12

  • 1金海鹰.有角膜屈光手术史患者的白内障手术[J].国外医学(眼科学分册),2002,26(1):42-45. 被引量:5
  • 2郭海科,金海鹰,张洪洋.角膜屈光手术后人工晶状体屈光力的计算[J].眼科研究,2009,27(2):144-148. 被引量:8
  • 3Jin H,Holzer MP,Rabsilber.T,et al.Intraocular lens power calculation after laser refractive surgery:corrective algorithm for corneal power estimation[J].J Cataract Refract Surg,2010,36(1):87-96.
  • 4Seitz B,Langenbucher A.Intraocular lens power calculation in eyes after corneal refractive surgery[J].J Refract Surg,2000,16(3):349-361.
  • 5Haigis W.Intraocular lens calculation after refractive surgery for myopia:Haigis-L formula[J].J Cataract Refract Surg,2008,34(10):1658-1663.
  • 6Fyodorov SN,Galin MA,Linksz A.Calculation of the optical power of intraocular lenses[J].Invest Ophthalmol,1975,14(8):625-628.
  • 7Haigis W.The Haigis formula.∥Shammas HJ.Intraocular lens power calculations[M].Thorofare:SLACK,2004:41-57.
  • 8Hoffer KJ.The Hoffer Q formula:a comparison of theoretic and regression formulas[J].J Cataract Refract Surg,1993,19(6):700-712.
  • 9Jin H,Rabsilber T,Ehmer A,et al.Comparison of ray-tracing method and thin-lens formula in intraocular lens power calculations[J].J Cataract Refract Surg,2009,35(4):650-662.
  • 10Preussner PR,Wahl J,Lahdo H,et al.Ray tracing for intraocular lens calculation[J].J Cataract Refract Surg,2002,28(8):1412-1419.

二级参考文献21

  • 1Awwad ST,Dwarakanathan S, Bowman RW. et al. Intraocular lens power calculation after radial keratotomy : estimating the refractive corneal power [ J]. J Cataract Refract Surg,2007,33: 1045 - 1050
  • 2Packer M, Brown LK, Hoffman RS, et al. Intraocular lens power calculation after incisional and thermal keratorefractive surgery [ J ]. J Cataract Refract Surg,2004,30: 1430-1434
  • 3Argento C, Cosentino MJ, Badoza D. Intraocular lens power calculation after refractive surgery [ J ]. J Cataract Refract Surg, 2003, 29 : 1346 - 1351
  • 4Olsen T,Corydon L, Gimbel H. lntraocular lens power calculation with an improved anterior chamber depth prediction algorithm [ J ]. J Cataract Refract Surg, 1995,21 (3) : 313 - 319
  • 5Holladay JT. Standardizing constants for ultrasonic biometry,keratometry, and intraocular lens power calculations [J]. J Cataract Refract Surg, 1997,23:1356 - 1370
  • 6Hoffer KJ. Biometry of 7500 cataract eyes [ J ]. Am J Ophthalmol, 1980, 90:360 - 368
  • 7Koch DD, Liu JF, Hyde LL, et al. Refractive complications of cataract surgery after radial keratotomy [ J ]. Am J Ophthalmol, 1989, 108 : 676 - 682
  • 8Howard G, Sun R, Geoffrey BK. Refractive error in cataract surgery after previous refractive surgery [ J ]. J Cataract Refract Surg, 2000, 26 : 142 - 144
  • 9Seitz B, Langenbucher A, Nguyen NX, et al. Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy [ J ]. Ophthalmology, 1999,106:693 - 702
  • 10Gimbel HV,Sun R. Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis[ J]. J Cataract Refract Surg, 2001,27:571 -576

共引文献9

同被引文献34

  • 1朱海丰,方志良,刘永基.一种确定角膜屈光术后人工晶体屈光度的新方法[J].光电工程,2007,34(4):55-59. 被引量:4
  • 2施明光,王波,邵婷婷.正常国人全角膜数字模型的建立[J].中华眼科杂志,2007,43(8):694-697. 被引量:12
  • 3Shirayama M, Wang L,Weikert MP, et al. Comparison of corneal powers obtained from 4 different devices [ J 1. Am J Ophthalmol,2009,148 (4) : 528-535. DOI : 10. 1016/j. ajo. 2009.04. 028.
  • 4Savini G, Barboni P, Carbonelli M, et al. Accuracy of Scheimpflug corneal power measurements for intraoeular lens power calculation[ J]. J Cataract Refract Surg,2009,35 (7) : 1193-1197. DOI: 10. 1016/j. jcrs. 2012.11. 022.
  • 5Savini G, Barboni P, Carbonelli M, et al. Agreement between pentacam and videokeratography in corneal power assessment[ J]. J Refract Surg, 2009,25 : 534-537.
  • 6Camps VJ, Pinero DP, Caravaca-Arens E, et al. New approach for correction of error associated with keratometric estimation of corneal power in keratoconus [ J ]. Cornea, 2014,33 ( 9 ) : 960 - 967. DOI : 10. 1097/ICO. 0000000000000190.
  • 7Rho CR, Na KS, Yoo YS, et al. Changes in anterior and posterior corneal parameters in patients with keratoconus after intrastromal corneal-ring segment implantation [ J ]. Curr Eye Res, 2013,38 ( 8 ) : 843-850. DOI: 10. 3109/02713683. 2013. 788723.
  • 8Tang M, Chen A,Li Y,et al. Corneal power measurement with Fourier- domain optical coherence tomography [ J ]. J Cataract Refract Surg, 2010,36 (12) : 2115-2122. DOI:10. 1016/j. jcrs. 2010.07. 018.
  • 9Holladay JT, Hill WE, Steinmueller A. Corneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery[ J]. J Refract Surg, 2009,25 ( 10 ) : 862 -868. DOI: 10. 3928/1081597X- 20090917 -07.
  • 10Hodge C, McAlinden C, Lawless M, et al. Intraocular lens power calculation following laser refractive surgery[ J/OL]. Eye Vis (Lond) ,2015,2 : 7 [ 2015-05 - 17 ]. http ://eandv. biomedcentral, corn/articles/ 10.1186/s40662-015-0017-3. DOI : 10.1186/s40662-015,.0017-3.

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部