摘要 通过对烷基化车间换热器腐蚀形貌、特征、产物、腐蚀介质、积垢、材料以及换热器流体特性的研究和分析,认为烷基化换热器的腐蚀失效主要由空泡腐蚀和湍流腐蚀引起,并提出了4项防腐蚀措施.经现场应用证明:改变设计或安排辅助管可以有效地减缓冷却管与管板结合部位的严重腐蚀. It was concluded from the studies and analysis of corrosion types, characteristics, corrosion products and corrosion media, fouling deposit and fluid properties of the heat exchangers in alkylation unit that the failure of the exchanger was mainly caused by bubbling corrosion and turbulent flow corrosion. Four corrosion protection measures were suggested. It was proven by site application that changing design or installing auxiliary pipes could effectively alleviate the severe corrosion at the joint of tubes and tube sheet.
出处 《石油化工腐蚀与防护》 CAS 1998年第4期25-27,45,共4页 Corrosion & Protection In Petrochemical Industry
关键词 烷基化 换热器 腐蚀 失效分析 防腐 炼油厂 heat exchanger, fatigue analysis, protection
  • 相关文献

同被引文献13

  • 1梁会军,胡传顺,秦华,叶唐,朱健,刘生基.酸再生塔气液相塔壁腐蚀速率的对比研究[J].压力容器,2006,23(9):12-15. 被引量:5
  • 2Dobis J D, Williams D G, Bryan D L. The effect of operating conditions on corrosion in HF alkylation units [C].//2004 NACE Conference Papers ,2004 : 1-11.
  • 3赵继文,焦大勇.烷基化装置氟化铁脱落原因的几点思考[A].2007年中国石油炼制技术大会论文汇编[C]//2007:875-879.
  • 4屈定荣,刘小辉,蒋秀等.氢氟酸烷基化装置腐蚀风险分析及对策[C].//石油和化工设备管道防腐技术与对策专题研讨会文集.2010:166-172.
  • 5Dobis J D. The top ten corrosion issues affecting HF alkylation units[C].//2007 NACE Conference Papers,2007:1-19.
  • 6项忠维.烷基化装置换热设备氢氟酸腐蚀原因分析及防护措施[c].//第三届全国现代设备管理及应用技术研讨会交漉论文集.2004:174-175.
  • 7Simonton J L,Barry L K. Evolution of new gasket type increases reliability in HF alkyation unit [C]J/2006 ASME Pressure Vessels and Piping Division Conference,2006:1-9.
  • 8田广,高占洋,宋玉柱.某锅炉省煤器管组腐蚀机理分析[J].锅炉制造,2013(6):37-38. 被引量:3
  • 9张莹,余建飞,张明,蔡萱.开式冷却水管腐蚀穿孔失效分析[J].工业水处理,2013,33(11):92-94. 被引量:5
  • 10邱征宇,郑蕾,潘鸿,廖晓玲.蒸汽锅炉节能器管失效机理分析[J].化学工程与装备,2017(4):147-151. 被引量:2