摘要
基于直流屏的电源监控系统的各模块功能划分与采样通道多等特点,设计了以MSP430单片机为控制核心,CPLD扩展端口的控制系统。比较分析了几种直流系统常用的绝缘检测方法,采用乒乓式变电桥测量法,实现了接地电阻的准确在线测量。现场运行表明,控制系统具有测量精度高、测量快速、可靠性高以及成本低等优点。
Based on function partition of modules and much sampling channels of power monitoring system for DC screen, a control system which takes MSP430 as control core and CPLD as extending ports is designed. The insulation methods of several DC systems are compared and analysed. A ping-pang variable bridge measurement is adopted. The ex- act on line detection of grounding resistance is realized. The field operation shows that the control system is high detecting precision, speeding detection, high reliability and low cost.
出处
《电气开关》
2010年第2期21-22,共2页
Electric Switchgear