期刊文献+

大型结构件数控加工厂房的通风空调系统 被引量:1

Ventilation and air conditioning system for large part numerical control machining buildings
下载PDF
导出
摘要 针对数控厂房体量大、金属加工液污染源分散的特点,提出了分层空调+周围捕获的方案。分别对重污染机床未隔离和隔离时厂房内的气雾浓度进行了分析计算,其结论验证了污染物的周围捕获效果优于集中捕获。采用分层空调+周围捕获方案能有效地清除厂房内的污染物。 In view of the characteristics of large space and dispersed pollutant sources of metal machining fluid,proposes a ventilation and air conditioning system scheme,i.e.stratified air conditioning plus peripheral collecting.Analyses and calculates the smog concentration in a machining building respectively on the conditions of isolated and non-isolated heavy pollution source machines,and the results prove that the effect of peripheral collecting is superior to that of centralized collecting.The effect of the scheme of stratified air conditioning plus peripheral collecting is satisfactory.
作者 赵雷昌
出处 《暖通空调》 北大核心 2010年第4期7-10,6,共5页 Heating Ventilating & Air Conditioning
关键词 大型数控厂房 金属加工液 气雾浓度 集中捕获 周围捕获 分层空调 large-scale numerical control machining building metal machining fluid smog concentration centralized collecting peripheral collecting stratified air conditioning
  • 相关文献

参考文献3

  • 1中国疾病预防控制中心职业卫生与中毒控制所.GBZ 2.1-2007工作场所有害因素职业接触限值化学有害因素[S].北京:人民卫生出版社,2007.
  • 2中国疾病预防控制中心环境与健康相关产品安全所.GB/T 18883-2002室内空气质量标准[S].北京:中国标准出版社,2003.
  • 3National Institute for Occupational Safety and Health (NOSH).What you need to know about occupational exposure to metal working fluids[EB/OL].[-2009].http://www,cdc.gov/niosh/98-116,html.