期刊文献+

三氯化铁分解-重铬酸钾滴定法测定直接还原铁中亚铁 被引量:9

Determination of iron(Ⅱ) in direct reduced iron by iron trichloride decomposition-potassium dichromate titration
下载PDF
导出
摘要 提出了用三氯化铁分解试样、重铬酸钾滴定法测定亚铁的分析方法。试样用三氯化铁溶液溶解,金属铁被氧化为二氯化铁进入溶液,亚铁留在沉淀中,过滤、分离,在隔绝空气的条件下,以盐酸和氟化钾溶液溶解沉淀,二苯铵磺酸钠为指示剂,用重铬酸钾标准溶液滴定。本文对方法中试剂浓度、用量、时间、滴定介质、干扰元素等影响因素进行试验,确定了三氯化铁溶液浓度和用量为100 g/L和30 mL、搅拌时间为20 min的最佳实验条件。该法测定直接还原铁中亚铁,相对标准偏差小于2%,加标回收率在98%-101%之间。 A determination method of iron(Ⅱ) in direct reduced iron was developed by iron trichloride decomposition-potassium dichromate titration.The sample was dissolved in irom trichloride solution.The metallic iron in sample was oxidized to ferrous chloride before entering into solution,while the iron(Ⅱ) remained in the sediment,which then was filtered and separated.In vacuum,the sediment was dissolved by hydrochloric acid and potassium fluoride.The solution was titrated with potassium dichromate standard solution with sodium diphenylamine sulfonate as indicator.The effects of concentration and dosage of reagent,time,titration medium and interference elements were investigated.The optimal experimental conditions were obtained: the concentration and dosage of iron trichloride were 100 g/L and 30 mL,and the stirring time was 20 min.This method was applied to the determination of iron(Ⅱ) in direct reduced iron,with the relative standard deviations(RSD) of less than 2 % and the recoveries in the range of 98 %-101 %.
作者 郑玲 陶俊
出处 《冶金分析》 CAS CSCD 北大核心 2010年第2期78-80,共3页 Metallurgical Analysis
关键词 直接还原铁 亚铁 三氯化铁 滴定法 direct reduced iron iron(Ⅱ) iron trichloride titration
  • 相关文献

参考文献4

  • 1GB/T 6730.8-1986铁矿石化学分析方法:重铬酸钾容量法测定亚铁量[S].
  • 2庄丽英.铁矿石中氧化亚铁测定方法的改进.冶金分析,1986,6(5):33-35.
  • 3陆晓明,金德龙,张志颖,陈英颖.ARL9800 X射线光谱仪测定烧结矿中氧化亚铁[J].理化检验(化学分册),2003,39(2):110-111. 被引量:1
  • 4王其华 马荣生.直接还原铁过程中金属铁和亚铁测定方法的研究.冶金分析,1985,5(1):114-17.

二级参考文献1

  • 1.ARL9800使用说明书:应用研究实验室[Z].瑞士,1999..

共引文献2

同被引文献237

引证文献9

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;