摘要 基于单U竖直地埋管换热器的热渗耦合传热模型进行大量的数值模拟计算,并用SPSS统计分析软件对计算结果进行了一元和多元回归分析,从而对地下埋管换热器单位井深换热量的影响因素,诸如岩土热物性、地下水流动、地埋管参数、循环液参数和运行模式等的影响程度进行了研究。用一元线性和非线性模型回归得到了单位井深换热量与各个参数的关系式;用多元线性模型回归得到了单位井深换热量的预测方程式,并分析了各因素影响的重要程度,用于指导工程实践。 In this paper,the numerical simulation is performed on the basis of the model describing heat transfer for single U-tube BHE(Borehole Heat Exchanger),and a single regression analysis and a multiple regression analysis on the heat exchange rate are conducted using the SPSS software.The influence of subsoil thermophysical property,groundwater velocity,dimension of BHE,heat exchanger fluid,and operational condition on the heat exchange rate is discussed.Both the linear and non-linear single regression techniques are used to develop a correlation of the heat exchange rate and the parameters,and the linear multiple regression technique is applied to obtain a multiple regression model for the prediction of the heat exchange rate.
出处 《制冷学报》 CAS CSCD 北大核心 2010年第2期11-16,共6页 Journal of Refrigeration
基金 国家自然科学基金(50806052)资助项目~~
关键词 工程热物理 单位井深换热量 一元回归分析 多元回归分析 Engineering thermophysics Transferring heat per unit of borehole depth Single regression analysis Multiple regression analysis
  • 相关文献

参考文献11

  • 1王勇,刘宪英,付祥钊.地源热泵及地下蓄能系统的实验研究[J].暖通空调,2003,33(5):21-23. 被引量:20
  • 2孙恒虎,崔建强,毛信理.地源热泵的节能机理[J].太阳能学报,2004,25(1):24-27. 被引量:20
  • 3V C Mei, C J Emerson. New approach for analysis of ground-coil design for applied heat pump systems[J]. ASHRAE Transactions, 1985, 91 (2B) : 1216-1224.
  • 4J D Deerman, S P Kavanaugh. Simulation of vertical u-tube ground-coupled heat pump systems using the cylindrical heat source solution[J]. ASHRAE Transactions, 1991, 97 (1) : 287-295.
  • 5C Yavuzturk, J D Spitler, S J Rees. A transient two- dimensional finite volume model for the simulation of vertical u-tube ground heat exchangers[J]. ASHRAE Transactions, 1999, 105 (Part 2) : 465-474.
  • 6Yian Gu, Dennis LO' Neal. Development of an equivalent diameter expression for vertical U-tube used in ground-coupled heat pumps[J]. ASHARE Transactions, 1998, 104: 347-355.
  • 7陶文铨.数值传热学[M].第2版.西安:西安交通大学出版社,2002:483-487.
  • 8唐大雄.工程岩土学[M].北京:地质出版社,1985..
  • 9A C Chiasson, S J Rees, J D SPitler. A preliminaryassessment of the effects of ground-water flow on closed- loop ground-source heat pump systems[J]. ASHRAE Transactions, 2000, 106 (1) : 380-393.
  • 10高青,乔广,于鸣,李明,白金玉.地温规律及其可恢复特性增强传热研究[J].制冷学报,2003,24(3):38-41. 被引量:23

二级参考文献21

  • 1丁勇 刘宪英 胡鸣明 等.地源热泵系统实验研究综述[A]..见:现代空调丛书:第3辑[C].北京:中国建筑工业出版社,2001.11-13.
  • 2长春地热开发公司.工程应用运行情况报告:吉林大学[A]..封闭式应用地温能量供热供冷技术开发报告集[C].长春:吉林大学,2001.12.
  • 3Stephen P K .Field Test for Ground Thermal Properties -Methods and Impact on Ground Source Heat Pump Design.ASHRAE Trans,2000,25(4) :851 - 855.
  • 4Stephen P K, Sally A M. Energy Use of Pumping Options for Ground Source Heat Pumps. ASHRAE Trans,2001,26(3) :589- 599.
  • 5Douglas C, Andres M ,O Christopher J I.Maintenance and Service Costs of Commericial Building Grouad Source Heat Pump System. ASHRAE Trans, 1998,23(2) :699 - 706.
  • 6Hu Mingming,Liu Xianying Experimental research on shallow coaxial tube ground-coupled heat pump for heating winter and cooling summer.In:Air conditioning in high rise bulldings’2000(ACHRB 2000).北京:中国建筑工业出版社,2000.284—289.
  • 7魏唐棣 胡鸣明 刘宪英.地源热泵地下埋管换热器的研究介绍[J].中国冷冻空调杂志,1999,(47):91-91.
  • 8刘宪英 胡鸣明.浅埋竖管换热器的地热源热泵冬季供热试验研究[J].中国学术期刊文摘,1999,5(8):1061-1062.
  • 9王勇 付祥钊 刘宪英.地源热泵地下管群换热器设计、施工的有关问题讨论[A]..1999年西南地区暖通制冷学术年会论文集[C].成都:西南交通大学出版社,1999.263-269.
  • 10何雪冰 丁勇 刘晓东.地热源热泵冬夏暖冷联供试验研究[J].冷冻与空调,2000,(3):175-175.

共引文献62

同被引文献101

引证文献15

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部