摘要 在高性能的永磁同步电机控制系统中,机械传感器的存在会使系统的成本增加,可靠性降低,容易受到外部环境的影响。在叙述永磁同步电机直接转矩控制原理的基础上,采用了一种基于转子磁链的转速估计方法,该方法根据定子磁链角和负载角确定出转子磁链角,进而估计出电机的转速。仿真和实验结果验证了该方法能够在电机全速范围内准确地估计出转速,具有优良的动静态性能,适合于永磁同步电机的直接转矩控制。 In the high performance of permanent magnet synchronous motor(PMSM) drive systems, mechanical sensors have disadvantages of high cost, low reliability and sensitivity to the environment. A speed estimation method using rotor flux linkage was described based on the principle of direct torque control(DTC) of PMSM. In this method, the rotor flux linkage angle is determined according to the stator flux linkage angle and the load angle, and the speed of PMSM can be estimated. Simulation and experiment results show that this method can be used in the whole speed range to estimate the motor speed well, the system has good dynamic and static characteristics and the method is Suitable to PMSM DTC.
出处 《电气传动》 北大核心 2010年第4期24-27,共4页 Electric Drive
关键词 永磁同步电机 直接转矩控制 定子磁链角 负载角 转子磁链角 permanent magnet synchronous motor direct torque control stator flux linkage angle, load angle rotor flux linkage angle
  • 相关文献

参考文献2

  • 1Haque M E,Zhong L,Rahman M F,et al.A Sensorless Speed Estimator for Application in a Direct Torque Controller of an Interior Permanent Magnet Synchronous Motor Drive,Incorporating Compensation of Offset Error[C]//PESC,2002,1,276-281.
  • 2Rahman M F,Zhong L,Haque M E,et al.A Direct Torque Controlled Interior Permanent Magnet Synchronous Motor Drive Without a Speed Sensor[J].IEEE Transactions on Energy Conversion,2003,18 (1):17-22.

同被引文献49

引证文献8

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部