摘要 本文使用流动注射分析仪测定了土壤样品中有效硅含量,工作曲线决定系数R2达0.9999以上,检出限为0.012μg/mL,相对标准偏差为0.04%-0.06%,样品加标回收率为97.89%-99.93%。实验证明该方法操作简便、线性好,其精密度、准确度、灵敏度都能符合分析工作要求。 The amount of available silicon in soil was determined by flow injection analysis approach in this paper.The determination coefficient (R^2) of this standardized work curve was found to be above 0.9999. The detection limit of this method was 0.012 μ g/mL, the relative standard deviation was in the range of 0.04%-0.06%, and the spike recoveries ranged from 97.89% to 99.93%.The experimentation has proved that this approach is characterized by simple operation and pretty good linear correlation, the precision, accuracy and sensitivity could meet the analytical requirements.
出处 《福建分析测试》 CAS 2010年第2期14-17,共4页 Fujian Analysis & Testing
基金 国家高技术研究发展专项经费资助(2007AA10Z232)
关键词 流动注射分析 测定 土壤 有效硅 flow injection analysis determination soil available Silicon