期刊文献+

Immobilization of Hemoglobin on Platinum Nanoparticles-Modified Glassy Carbon Electrode for H_2O_2 Sensing

Immobilization of Hemoglobin on Platinum Nanoparticles-Modified Glassy Carbon Electrode for H_2O_2 Sensing
原文传递
导出
摘要 This work described an amperometric hydrogen peroxide (H2O2) biosensor based on immobilization of hemoglobin (Hb) on a glassy carbon (GC) electrode modified by platinum nanoparticles, which was prepared by an in situ chemical reductive growth method. The electrochemical impedance measurements confirmed that the Hb was immobilized on the platinum nanoparticles-modified glassy carbon surface and has a synergistic effect with platinum nanoparti- cles in improving the catalytic reduction of H2O2. The Hb immobi- lized platinum nanoparticles-modified GC (Hb/Pt/GC) electrode displays an effective catalytic response to the reduction of H2O2. A linear dependence of the catalytic current versus H2O2 concentration was obtained in the range of 5.0×10 6 to 4.5×10^-4 mol·L^-1 with a detection limit (S/N=3) of 7.4×10^-7 mol·L-1. This work described an amperometric hydrogen peroxide (H2O2) biosensor based on immobilization of hemoglobin (Hb) on a glassy carbon (GC) electrode modified by platinum nanoparticles, which was prepared by an in situ chemical reductive growth method. The electrochemical impedance measurements confirmed that the Hb was immobilized on the platinum nanoparticles-modified glassy carbon surface and has a synergistic effect with platinum nanoparti- cles in improving the catalytic reduction of H2O2. The Hb immobi- lized platinum nanoparticles-modified GC (Hb/Pt/GC) electrode displays an effective catalytic response to the reduction of H2O2. A linear dependence of the catalytic current versus H2O2 concentration was obtained in the range of 5.0×10 6 to 4.5×10^-4 mol·L^-1 with a detection limit (S/N=3) of 7.4×10^-7 mol·L-1.
出处 《Wuhan University Journal of Natural Sciences》 CAS 2010年第2期160-164,共5页 武汉大学学报(自然科学英文版)
基金 Supported by Science Research Foundation of Huazhong University of Science and Technology (2006Z002A)
关键词 hydrogen peroxide platinum nanoparticles hemo-globin electrocatalytic activity hydrogen peroxide platinum nanoparticles hemo-globin electrocatalytic activity
  • 相关文献

参考文献22

  • 1Notsu H, Tatsuma T, Fujishima A. Tyrosinase-modified boron-doped diamond electrodes for the determination of phenol derivatives[J]. Journal of Electroanalytical Chemistry and Interfaeial Electrochemistry, 2002, 523(1-2): 86-92.
  • 2Hurdis E C, Romeyn H. Accuracy of determination of hydrogen peroxide by cerate oxidimetry[J]. Analytical Chemistry, 1954, 26(2): 320-325.
  • 3Demmano G, Selegny E, Vincent J C. Active transport of protons and electrons driven by redox enzyme reactions via G3P/DHAP shuttle, a model, kinetics of activity and evolution of redox potential gradients[J]. Bioelectrochemistry and Bioenergetics, 1996, 40(2): 239-247.
  • 4Nakashima K, Maki K, Kawaguchi S, et al. Peroxyoxalate chemiluminescence assay of hydrogen peroxide and glucose using 2,4,6,8-tetrathio-morpholinopyrimido [5,4-d] pyrimidine as a fluorescent component[J]. Analytical Sciences, 1991,7(5) 709-714.
  • 5Xiao Y, Chen H, Ju H. A Reagentless hydrogen peroxide sensor based on incorporation of horseradish peroxidase in poly(thionine) film on a monolayer modified electrode[J]. Analytica Chimica Acta, 1999, 391(3): 299-306.
  • 6Wang L, Wang E. A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized on colloidal Au modified ITO electrode[J]. Electrochemistry Communications, 2004, 6(2): 225-229.
  • 7Guibault, G G, Lubrano G J. An enzyme electrode for the amperometric determination of glucose[J]. Analytica Chimica Acta, 1973, 64(3): 439-455.
  • 8Wang J, Chen L, Liu J. Critical comparison of metalized and mediator-based carbon paste glucose biosensors[J]. Electroanalysis, 1997, 9(4): 298-301.
  • 9Lei C X, Hu S Q, Gao N, et al. An amperometric hydrogen peroxide biosensor based on immobilizing horseradish peroxidase to a nano-Au monolayer supported by sol-gel derived carbon ceramic electrode[J]. Bioelectrochemistry. 2004, 65(1) 33-39.
  • 10Ricci F, Palleschi G. Sensor and biosensor preparation, optimisation and applications of Prussian blue modified electrodes[J]. Biosensors and Bioelectronics, 2005, 21(3): 389- 407.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部