期刊文献+

UNSTEADY FLOW ANALYSIS AND EXPERIMENTAL INVESTIGATION OF AXIAL-FLOW PUMP 被引量:113

UNSTEADY FLOW ANALYSIS AND EXPERIMENTAL INVESTIGATION OF AXIAL-FLOW PUMP
原文传递
导出
摘要 The three-dimensional unsteady turbulent flow in axial-flow pumps was simulated based on Navier-Stoke solver embedded with k - ε RNG turbulence model and SIMPLEC algorithm. Numerical results show that the unsteady prediction results are more accurate than the steady results, and the maximal error of unsteady prediction is only 4.54%. The time-domain spectrums show that the static pressure fluctuation curves at the inlet and outlet of the rotor and the outlet of the stator are periodic, and all have four peaks and four valleys. The pressure fluctuation amplitude increases from the hub to the tip at the inlet and outlet of the rotor, but decreases at the outlet of the stator. The pressure fluctuation amplitude is the greatest at the inlet of the rotor, and the average amplitude decreases sharply from the inlet to the outlet. The frequency spectrums obtained by Fast Fourier Transform (FFT) show that the dominant frequency is approximately equal to the blade passing frequency. The static pressure on the pressure side of hydrofoil on different stream surfaces remains almost consistent, and increases gradually from the blade inlet to the exit on the suction side at different time steps. The axial velocity distribution is periodic and is affected by the stator blade number at the rotor exit. The experimental results show that the flow is almost axial and the pre-rotation is very small at the rotor inlet under the conditions of 0.8 QN -1.2 QN Due to the clearance leakage, the pressure, circulation and meridional velocity at the rotor outlet all decrease near the hub leakage and tip clearance regions. The three-dimensional unsteady turbulent flow in axial-flow pumps was simulated based on Navier-Stoke solver embedded with k - ε RNG turbulence model and SIMPLEC algorithm. Numerical results show that the unsteady prediction results are more accurate than the steady results, and the maximal error of unsteady prediction is only 4.54%. The time-domain spectrums show that the static pressure fluctuation curves at the inlet and outlet of the rotor and the outlet of the stator are periodic, and all have four peaks and four valleys. The pressure fluctuation amplitude increases from the hub to the tip at the inlet and outlet of the rotor, but decreases at the outlet of the stator. The pressure fluctuation amplitude is the greatest at the inlet of the rotor, and the average amplitude decreases sharply from the inlet to the outlet. The frequency spectrums obtained by Fast Fourier Transform (FFT) show that the dominant frequency is approximately equal to the blade passing frequency. The static pressure on the pressure side of hydrofoil on different stream surfaces remains almost consistent, and increases gradually from the blade inlet to the exit on the suction side at different time steps. The axial velocity distribution is periodic and is affected by the stator blade number at the rotor exit. The experimental results show that the flow is almost axial and the pre-rotation is very small at the rotor inlet under the conditions of 0.8 QN -1.2 QN Due to the clearance leakage, the pressure, circulation and meridional velocity at the rotor outlet all decrease near the hub leakage and tip clearance regions.
出处 《Journal of Hydrodynamics》 SCIE EI CSCD 2010年第1期35-43,共9页 水动力学研究与进展B辑(英文版)
基金 Project supported by the National High Technology Research and Development Program of China (863 Program,Grant No.2007AA05Z207) the Graduate Student Innovation Foundation of Jiangsu Province (Grant No.CX08B_064Z) the National Science and Technology Support Program (Grant No.2008BAF34B15)
关键词 axial-flow pump unsteady flow pressure fluctuation high efficiency flow field measurement axial-flow pump, unsteady flow, pressure fluctuation, high efficiency, flow field measurement
  • 相关文献

参考文献3

二级参考文献19

  • 1叶方明,高红,林万来.后置导叶型喷水推进泵总特性及三维流场[J].上海交通大学学报,2005,39(9):1409-1412. 被引量:8
  • 2WANG Fu-jun LI Yao-jun CONG Guo-hui WANG Wen-e WANG Hai-song.CFD SIMULATION OF 3D FLOW IN LARGE-BORE AXIAL-FLOW PUMP WITH HALF-ELBOW SUCTION SUMP[J].Journal of Hydrodynamics,2006,18(2):243-247. 被引量:37
  • 3Harrison S. Secondary loss generation in a linear cascade of high-turning turbine blades [J]. ASME Journal of Turbomaehinery, 1990,112 : 618-624.
  • 4Miner S M. CFD analysis of an axial flow pump impeller using a coarse grid [C]// Proceedings of 1997 ASME FEDSM. Vancouver, Canade: ASME Press, 1997.
  • 5Myers K J,Ward R W, Bakker A. A digital particle image velocimetry investigation of flow field instabilities of axial-flow impellers [J]. Journal of Fluids Engineering, Transactions of the ASME, 1997, 119 (3): 623-632.
  • 6Uzol O,Chow Y C,Katz J,etal. Experimental investigation of unsteady flow flied within a two-stage axial turbomachine using particle image velocimetry [J]. Journal of Turbomaehinery, 2002,124 : 542-552.
  • 7Melling A. Tracer particles and seeding for particle image velocimetry [J]. Meas Sci Technol, 1997,8 (12) : 1406-1416.
  • 8Noguera R,Rey R,Massouh F.Design and analysis of axial pumps[A].Proceedings of the ASME Second Pumping Machinery Symposium[C].Washington:ASME Fluids Engineering Division,1993.95-111.
  • 9White J D,Holloway A G L,Gerber A G.Predicting turbine performance of high specific speed pumps using CFA[A].Proceedings of ASME Fludis Engineering Division Summer Conference[C].Houston:ASME Fluids Engineering Division,2005.125-131.
  • 10Chu S,Dong R,Katz J.Relationship between unsteady flow,pressure fluctuations,and noise in a centrifugal pump-part B:effects of blade-tongue interactions[J].Journal of Fluids Engineering,Transactions of the ASME,1995,117(1):30-35.

共引文献184

同被引文献735

引证文献113

二级引证文献912