期刊文献+

Optimizing Monte-Carlo simulation of the photon transmission in high-scatterance matter based on fiber sensing

Optimizing Monte-Carlo simulation of the photon transmission in high-scatterance matter based on fiber sensing
原文传递
导出
摘要 In order to shorten the operation time of the Monte-Carlo simulation of photon transmission in the thicker high-scatterance matter,the fiber is chosen as the receiving device.At the same time,the light source and the receiving surface are aligned.According to the distinction of the anisotropic factor(g),increasing the restricted conditions could improve the simulation speed greatly.And the approximate restricted conditions could cut down the waste time of operations.Simulation results indicate that compared with the Monte-Carlo simulation,the optimized one could save 67% time,and ensure the precision higher than 0.7% in the thicker matter. In order to shorten the operation time of the Monte-Carlo simulation of photon transmission in the thicker high-scatterance matter,the fiber is chosen as the receiving device.At the same time,the light source and the receiving surface are aligned.According to the distinction of the anisotropic factor(g),increasing the restricted conditions could improve the simulation speed greatly.And the approximate restricted conditions could cut down the waste time of operations.Simulation results indicate that compared with the Monte-Carlo simulation,the optimized one could save 67% time,and ensure the precision higher than 0.7% in the thicker matter.
出处 《Optoelectronics Letters》 EI 2010年第3期237-240,共4页 光电子快报(英文版)
基金 supported by the National Natural Science Foundation of China (No. 60674111)
  • 相关文献

参考文献1

二级参考文献21

  • 1马振鹤,王瑞康,张帆,王鹏,姚建铨.快速高分辨率的频谱光学相干层析成像系统研究[J].纳米技术与精密工程,2005,3(3):232-235. 被引量:8
  • 2黄丽娜,俞晓峰,丁志华.光学相干层析成像系统中双通快速扫描光学延迟线的数值分析[J].光子学报,2005,34(11):1663-1665. 被引量:9
  • 3郑羽,李刚,刘晶晶,张泰石,林凌.在CSOCT系统中抑制线性相移误差的校正算法[J].光学精密工程,2007,15(5):753-760. 被引量:2
  • 4LEITGEB R, HITZENBERGER C K, FERCHER A F. Performance of Fourier domain vs. time domain optical coherence tomography[J]. Optics Express, 2003,11 (8) : 899.
  • 5FERCHER A F,DREXLER W. Optical coherence tomography-principles and applications[J]. Rep. Prog. Phys. 2003, 66:239-303.
  • 6NASSIF N A, GENSE B. In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve[J]. Optics Express ,2004,12(3) : 367.
  • 7TOMLINS P H, WANG R K. Theory, developments and applications of optical coherence tomography[J]. J. Phys. D, Appl. Phys. ,2005, 38(15): 2519-2535.
  • 8LEITGEB R A,DREXLER W,FERCHER A F. Ultrahigh resolution fourier domain optical coherence tomography [J]. Optical Express, 2004, 12(12): 2156-2165.
  • 9LEITGEB R A,SCHMETTERER L,DREXLER W,et al.. Real-time assessment of retinal blood flow with ultrafast acquisition by color doppler fourier domain optical coherence tomography[J]. Optical Express, 2003, 11(23): 3116-3121.
  • 10CENSE B,NASSIF N A,JOHANNES F,et al.. Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography[J]. Optical Express, 2004, 12(11): 2435-2447.

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部