期刊文献+

单开门椎管成形侧块钢板内固定术治疗多节段颈椎管狭窄症 被引量:20

原文传递
导出
摘要 目的:探讨单开门椎管成形侧块钢板内固定术对多节段颈椎管狭窄症的治疗效果。方法:对27例多节段颈椎管狭窄患者行单开门椎管成形侧块钢板内固定术。均取颈后路正中切口,采用An方法进行侧块螺钉固定。结果:随访10~27个月,平均17个月。术中未发生神经、脊髓损伤及椎动脉损伤。经JOA评分评估,本组优15例,良6例,好转2例,无效4例,有效率85.2%,优良率77.8%。结论:单开门椎管成形侧块钢板内固定术治疗多节段颈椎管狭窄减压充分、内固定坚强,疗效满意,尤其适用于伴有节段性不稳的多节段颈椎管狭窄症。
出处 《中华实用诊断与治疗杂志》 2010年第4期395-396,共2页 Journal of Chinese Practical Diagnosis and Therapy
  • 相关文献

参考文献6

  • 1An H S, Gordin R S, Renner K. Anatomic considerations for plate-screw fixation of the cervical spine[J]. Spine, 1991,16 (10 Suppl) :s548-551.
  • 2Ratliff J K, Cooper P R. Cervical laminoplasty: a critical review [J]. J Neurosurg,2003,98(3 Suppl):230-238.
  • 3王少波,蔡钦林,党耕町,李迈,王立舜,张凤山.单开门颈椎椎管扩大成型术的远期疗效观察[J].中华骨科杂志,1999,19(9):519-521. 被引量:138
  • 4Ebraheim N A, Klausner T, Xu R, et al. Safe lateral-mass screw lengths in the Roy Camille and Magerl techniques. An anatomic study[J]. Spine, 1998,23(16) : 1739-1742.
  • 5赵学凌,赵宏斌,王兵,李林芝,朱晓松,张春强.经后路联合使用侧块钢板螺钉和椎弓根钉内固定治疗下颈椎损伤[J].中华外科杂志,2005,43(4):215-217. 被引量:12
  • 6Roy-Camille R R, Sailant G, Mazel C. Internal fixation of the unstable cervical spine by posterior osteosynthesis with plate and screws// Cervical Spine Research Socity. The cervical spine [M]. 2nd ed. Philadelphia : JB Lippincott, 1989 : 390-404.

二级参考文献11

  • 1Albert TJ, Klein GK, Joffe D, et al. Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology.Spine,1998,23:1596-1599.
  • 2Deen HG, Birch BD, Wharen RE, et al. Lateral mass screw-rod fixation of the cervical spine: a prospective clinical series with 1-year follow-up. Spine J,2003,6:489-495.
  • 3Weis JC, Cunningham BW, Kanayama M,et al. In vitro biomechanical comparison of multistrand cables with conventional cervical stabilization. spine,1996,21:2108-2114.
  • 4Swank ML, Sutterlin CE, Bossons CK, et al. Rigid internal fixation with lateral mass plates in multilevel anterior and posterior reconstruction of the cervical spine. Spine, 1997, 22:274-282.
  • 5Smith ME, Cibischino M, Langrane NA, et al. A biomechanical study of a cervical spine stabilization device: Roy-Camille plates.Spine,1997,22:38-43.
  • 6Jens RC, Paul AA, Christopher P, et al. Posterior instrumentation of the unstable cervicothoracic spine.J Neurosurg,1996,84:552-558.
  • 7蔡钦林,中华骨科杂志,1990年,10卷,325页
  • 8蔡钦林,中野升.“单开门”椎管扩大术治疗颈椎椎管狭窄症疗效观察:...[J].中华骨科杂志,1990,10(5):325-327. 被引量:70
  • 9孙宇,王超,党耕町,王少波,齐强,王志国.颈椎侧块钢板螺钉内固定术治疗下颈椎骨折脱位[J].中华骨科杂志,2000,20(3):150-153. 被引量:54
  • 10尹庆水,张余,刘景发,曹正霖,夏虹,权日,钟润泉,章莹,昌耘冰,吴文,徐国洲,区锦华.AXIS颈椎侧块钢板治疗下颈椎不稳临床应用初步报告[J].中华骨科杂志,2001,21(4):201-204. 被引量:29

共引文献148

同被引文献159

引证文献20

二级引证文献118

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部