总结了建筑节能保温材料检测中容易造成数据偏差的一些问题;分析了导热系数仪的原理,并据此提出对其选用的建议;强调了几种保温材料试验中的注意事项,以期提高检测数据的准确性。
Some problems may cause the data deviation in the testing of building insulation raw materials is generalized; the principles of the heat conduction coefficient detector is analyzed, and the selection advice is put forward according to this; precautions of several insulation materials testing is emphasized to raise the accuracy of the testing result.
出处
《工程质量》
2010年第4期19-20,24,共3页
Construction Quality
关键词
建筑节能
保温
导热系数
building energy efficiency
insulation