摘要
本钢5号高炉子1996年4月1日停炉中修,介绍了5号高炉中修前的生产操作情况及存在的问题,总结了炉皮、耐火砖衬、冷却壁的破损情况,分析了破损原因,并提出了改进意见及延长高炉使用寿命的措施。
The No. 5 BF of Bedri Iron & Steel Co. was blown off for intermediate repairon April 1, 1996. The operation condition and problems before intermediate rapair are intro-duced. Breakage of furnace shell, refractory lining and stave are summarized. The damage causeare analyzed, and rneasures about improvement and prolonging blast fumace life are put for-ward.
出处
《鞍钢技术》
CAS
1998年第11期50-53,F004,共5页
Angang Technology