期刊文献+

核电站用1E级(K3类)电缆相关标准的讨论 被引量:3

Discussion on the Relevant Standards about Category 1E Class K3 Cables for Nuclear Power Station
下载PDF
导出
摘要 目前我国核电建设已进入了快速发展的时期,核电站用电缆的需求也随之增加。由于我国还没有该类产品的国家标准,国内各企业在开发核电站用电缆过程中大多参照IEEE或RCC-E标准。本文按照GB22577—2008《核电站用1E级电缆通用要求》标准中关于1E级电缆的分类规定,介绍了国外标准及规范对于1E级(K3类)电缆的试验要求,供有关人员参考。 Now the construction of China' s nuclear power generation has entered a phase of rapid development. The demand for cables for nuclear power station in increasing accordingly. Due to absence of Chinese National standards about this kind of cables, related IEEE or RCC-E standards are mostly referenced by the domestic manufacturers in R & D of nuclear power cables. In this paper, the test requirements for category 1E class K3 cables in foreign code and standard are presented according to the classification of category 1E cables in GB 22577--2008 Category 1E Cables for Nuclear Power Station; General requirements, in order to provide references for the testing persons concerned.
作者 王岩
出处 《电线电缆》 2010年第2期33-35,共3页 Wire & Cable
关键词 核电站用1E级(K3类)电缆 标准 试验 讨论 Category 1E class K3 cables for nuclear power station standard testing discussion
  • 相关文献

参考文献2

  • 1IEEE Std 383-2003《IEEE Standard for Qualifying Class IE Electric Cables and Field Splices for Nuclear Power Generating Stations》[S].
  • 2IEEE Std 383-1974《IEEE Standard for Type Test of Class 1E Electric Cables,Field Splices,and Connections for Nuclear Power Generating Stations》[S].

同被引文献30

  • 1王福志,姜松奕,郑红,刘晓光.核电站用1E级电缆结构设计及有关试验的探讨[J].电线电缆,2006(6):14-18. 被引量:9
  • 2王乐,徐曼,谢大荣,曹晓珑.一种新型有机硅(ZD)在无卤阻燃电缆料中的应用[J].高分子材料科学与工程,2007,23(2):222-226. 被引量:9
  • 3Mohammed A. Bahattab,Jaroslav Mosná?ek,Ahmed A. Basfar,Tariq M. Shukri.Cross-linked poly(ethylene vinyl acetate) (EVA)/low density polyethylene (LDPE)/metal hydroxides composites for wire and cable applications[J]. Polymer Bulletin . 2010 (6)
  • 4G. I. Meshchanov,I. B. Peshkov.Innovative approaches in domestic cable engineering[J]. Russian Electrical Engineering . 2010 (1)
  • 5V. N. Gordeev,M. A. Shimanovskaya.Statics of nonlinear elastic cable-stayed systems with slipping flexible cables[J]. International Applied Mechanics . 2006 (5)
  • 6Masayuki I.Service life prediction of polymeric materials. . 2009
  • 7Sleights J E.An evaluation of old armored cables in buildingwiring systems. Fire Techn . 2011
  • 8Thomas W.Power systems,submarine power cables. . 2009
  • 9Milani G,Milani F.Genetic algorithm for the optimizationof rubber insulated high voltage power cables productionlines. Computers and Chemical Engineering . 2008
  • 10Hwang I,Lee J S,Asce M,et al.Isolation system for vibra-tion control of stay cables. Journal of Engineering Mechanics ASCE . 2009