摘要 目的探讨多层螺旋CT血管造影(MSCTA)技术与高压注射器应用的匹配问题。方法选取720例(年龄18~85岁,平均60.2岁;男465例,女255例)作CT检查的患者,使用Siemens公司SOMATOMSensation 64层螺旋CT扫描机及德国Ulich高压注射器和优维显370mgI/ml浓度的非离子型对比剂静脉团注,观察CT的影像效果。结果高压注射器与MSCTA扫描的合理匹配可取得良好的影像效果。结论正确熟练掌握高压注射器,使MSCTA扫描时间和团注速度、剂量相匹配有助于提高影像诊断疾病的准确性。 Objective To investigate the operating matching problems of multi-slice spiral computed tomography angiography (MSCTA) and using high-pressure mechanical injector in multi-slice spiral computed tomography (MSCT). Methods Seven hundred and twenty cases aged from 18 to 85 were studied. The average age was 60. 2 years. In these cases, 465 cases were male and 255 cases were female. SOMATOM sensation 64-slice spiral CT, ulich hlgh-pressure mechanical injector and 370 mgL/ml uhravist for injection were used. Results Good imaging quality can be achieved when high-pressure mechanical injector was employed reasonably during MSCTA. Conclusion Skillful mastering of operating high-pressure mechanical injector and matching MSCTA scanning time with injection speed and dose are very helpful to raise the accuracy of clinical diagnosis.
作者 李红尧
出处 《中国临床新医学》 2010年第4期360-362,共3页 CHINESE JOURNAL OF NEW CLINICAL MEDICINE
关键词 高压注射器 多层螺旋CT血管造影 对比剂 High-pressure mechanical injector Multi-slice spiral computed tomography angiography Contrast media
  • 相关文献

参考文献3

二级参考文献14

  • 1王锦良,李天然,钱根年,肖慧,李铭山.多层螺旋CT血管造影的影像分析[J].临床放射学杂志,2005,24(11):1026-1027. 被引量:24
  • 2童双立.多层螺旋CT的新进展[J].CT理论与应用研究(中英文),2005,14(4):50-53. 被引量:25
  • 3杨秀军,彭仁罗.脑血管畸形磁共振血管成像与脑血管造影对照研究[J].临床放射学杂志,1997,16(2):69-72. 被引量:9
  • 4Leclere X, Gauvrit JY, Pruvo JP. Usefulness of CT angiography with volume rendering after carotid angioplasty and stenting. AJR, 2000, 174(3):820
  • 5Anderson GB, Findlay JM, Steinke DE, et al. Experience with computed tomagraphy for detection of intracranial aneurysms in the setting of acute subarachnoid hemorrhage. Neurosug, 1997,41 ( 3 ) :522
  • 6Lindrt EV, perneczky A. The supraorbital keyhole approach to supratentorial aneurysms: concept and technique. Surg Neurol , 1998,49 (5) :481
  • 7Rohnert W, Hanig V, Hietschold V, et al. Detection of aneurysm in subarachnoid hemorrhage-CT angiography vs. digital subtraction angiography. Aktuelle Radiol, 1998,8(2) :63
  • 8Matsumoto M, Sato M, Nakano M, et al. Three-dimensional computerized tomography angiography guided surgery of acutely mpturfed cerebral aneurysms. J Neurosurg, 2001,94(5) :718
  • 9Yasui T, Kishi H, Komiyama M, et al. The limitations of three-dimensional CT angiography (3D-CTA) in the diagnosis of cerebral aneurysms. No Shinkei C, eka,2000,28( 11 ) :975
  • 10Fishman EK,Horton KM,Urban BA.Multidetector CT angiography in the evaluation of pancreatic caroinoma:preliminary observations[J].J Comput Assist Tomogr,2000,24 (6):849-853.

共引文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部