期刊文献+

Optimization of Operational Parameters in a Three Phase AC / DC Reactive Power Compensator 被引量:1

Optimization of Operational Parameters in a Three Phase AC / DC Reactive Power Compensator
下载PDF
导出
摘要 AC / DC converter is a kind of devices applicable to reactive power compensation. Three parameters including losses, Total Harmonic Distortion (THD) and compensation capacity have important role in designing procedure that these parameters are affected by the firing angle. Consideration trade of between these parameters can cause be selected suitable firing angle for optimal working of the compensator. In this paper is defined an objective function which includes the above parameters. This objective function is optimized through appropriate weighting factor for any parameters and the optimal firing angle will be obtained. So, the mention parameters can be selected optimally.
出处 《Journal of Energy and Power Engineering》 2010年第3期52-57,共6页 能源与动力工程(美国大卫英文)
关键词 Optimal firing angle compensator capacity compensator loss harmonic reduction 直流转换器 无功补偿 三相交流 参数优化 操作 目标函数 总谐波失真 补偿方法
  • 相关文献

参考文献19

  • 1D.A. Deib, H.W. Hill, Optimal firing-angle control of cascaded HVDC converters for minimum reactive power demand, Applied Power Electronics Conference and Exposition, 1993. APEC '93, in: Conference Proceedings 1993, Eighth Annual, March 7-11, 1993, pp. 662-667.
  • 2D.A. Deib, H.W. Hill, W. Shepherd, Optimal firing-angle control of cascaded HVDC converters for minimum harmonic currents, Industrial Electronics, Control, and Instrumentation, in: Proceedings of the IECON '93, International Conference, Nov. 15-19, Vol. 2, 1993, pp. 1071-1076.
  • 3D.A. Deib, H.W. Hill, Utilization of three-phase thyristorcontrolled AC-DC converters for reactive power compensation with minimum losses, in: Applied Power Electronics Conference and Exposition, APEC '95. Conference Proceedings 1995, Tenth Annual, March 5-9, Vol. 2, 1995, pp. 627-632.
  • 4D.A. Deib, H.W. Hill, W. Shepherd, AC / DC control for thyristor-controlled reactors for reactive power compensation, in: 20th International Conference on Industrial Electronics, Control and Instrumentation, IECON '94., Vol. 1, Sept. 5-9, 1994, pp. 355-359.
  • 5I.G. Park, J.T. Yoon, S.I Kim, A thyristor-controlled static condenser with the double firing phase control, IEEE Ransactions on Industry Applications 33 (6) (1997).
  • 6Z. Ye, Three-phase reactive power compensation using a single-phase AC / AC converter. IEEE Transactions on Power Electronics 14 (5) (1999) 816-822.
  • 7IEEE Power Engineering Society / CIGRE, FACTS Overview. New York: IEEE Press, 1995.
  • 8IEEE Power Engineering Society, FACTS Applications. New York, IEEE Press, 1996.
  • 9Y.H. Song, A.T. Johns (Eds.), Flexible AC transmission systems (FACTS), London, U.K., IEEE Press, 1999.
  • 10N.G. Hingorani, L. Gyugyi, Understanding FACTS. New York, IEEE Press, 1999.