期刊文献+

多层螺旋CT低剂量扫描在胸部体检中的应用 被引量:10

Application of Low-dose Multi-slice Spiral CT Scan for Chest Physical Examination
下载PDF
导出
摘要 目的探讨多层螺旋CT小毫安低剂量肺部体检的临床应用价值。方法运用多层螺旋CT对50例受检者行肺部扫描,扫描条件为120kV,25或50mAs,并进行标准与肺模式两种方式重建。结果 50例受检者中发现病变13例。结论多层螺旋CT小毫安低剂量肺部体检普查值得推广。 Objective To evaluate the clinical application value of small- mAs and low-dose muhai-slice spiral CT scan in chest physical examination. Methods Fifty patients underwent lung scanning with zhe multi-slice spiral CT and the scan parameters were as follows:120kV and 25 or 50mAs. And then the standard and lung models were reconstructed. Results We found lesions in 13 of the 50 patients. Conclusion It is worth promoting use of the low-dose multi-slice spiral CT scan in chest physical examination.
出处 《中国现代医生》 2010年第12期59-60,F0003,共3页 China Modern Doctor
关键词 多层螺旋CT 低剂量扫描 肺部 体检 Multi-slice spiral CT Low-dose scan Chest Physical examination
  • 相关文献

参考文献7

二级参考文献16

  • 1李铁一,李辉,肖国文,王铁根.胸部螺旋CT技术参数的最佳选择及应用[J].中华放射学杂志,1995,29(12):829-833. 被引量:15
  • 2[1]连波著.放射卫生防护.洛阳:黄河出版社,1998.143-160
  • 3[2]Naidich DP. Marshall CH, Gribbin C , et al . Low - dose CT of the lungs: preliminary observations. Radiology, 1990,175: 729- 731
  • 4[3]Kaneko M, Eguchi K, Ohmatsu Hi et al. peripheral lung cancer:screening and detection with low - dose spiral CT versus radiography. Radiology , 1996, 201: 798 - 802
  • 5[4]Nitta N, Takahashi M, Murata K, et al . Ultra low- dose helical CT of the chest . AJR, 1998, 171: 383 - 385
  • 6[5]Rusinek, H, Naidich, D. P, Mc Guinness, G, et al: pulmonary nodule detection: Low- dose Versus conventional CT. Radiology,1998, 209: 243- 249
  • 7Sone S,Li F,Yang ZG,et a1.Results of three-year mass screening programme for lung cancer using mobile low-dose spiral computed tomography scanner.British Journal of Cancer.2001,84:25.
  • 8Henschke CI,Miettinen OS,Yankelevitz DF.et a1.Early lung cancer action project:overall design and findings baseline screening.Lancet.1999,354:99.
  • 9Diederich S.Lenzen H,Windmann R,et a1.Pulmonary nodules:experimental and clinical studies at low-dose CT.Radiology.1999.213:289.
  • 10Strauss GM t Gleason RE,Sugar Baker DJ.Screening for lung cancer,another look:a different view.Chest,1997.111:754.