期刊文献+

ICP-MS冷浆法测定超高纯氨水中的痕量铁

Determination of trace Iron in Ultra-high Pure Ammonia by ICP-MS With Cold Plasma Technique
下载PDF
导出
摘要 用冷浆技术对超高纯氨水(29%)中10-10以下铁含量进行了测定研究。用标准加入法对加标回收率进行了测定。结果表明:在冷浆条件下,10-10以下铁含量线性可以达到0.999 8,定量是准确的。 Trace iron(below 1.0×10-10) in ultra-high pure ammonia(29%) was determined by ICP-MS with cold plasma technique.Recovery of standard addition was also determined with standard addition method.the results show that under the cold plasma condition,linear of iron content(below 1.0×10-10)can reach 0.999 8,quantitative analysis is accurate.
作者 王元有
出处 《辽宁化工》 CAS 2010年第4期451-453,共3页 Liaoning Chemical Industry
关键词 冷浆技术 超高纯氨水 Cold Plasma Technique Ultre ultra-high pure ammonia Iron
  • 相关文献

参考文献6

  • 1Jiang S J,Houk R S et al.Anal.Chem,1988,60:12-17.
  • 2Sakara K and Kawabara K.Spetrochim Acta,1994,49B:1 027.
  • 3D.A斯科格.仪器分析原理,下册[M].吉林大学化学系分析化学教研室,译.上海:上海科学技术出版社,1981.
  • 4Wahlen,R.,Evans,L.,Turner,J.,Hearn,R.,The Use of Collision/Reaction Cell ICP-MS for the Simultaneous Determination of 18 Elements in Blood and Serum Samples,2005,Agilent pub 5 989-2 885EN.
  • 5Technical Description of Agilent 7500cs ORS ICP-MS,5988-9881EN,July 2003.
  • 6A Comparison of the Relative Cost and Productivity of Traditional Metals Analysis Techniques versus ICP-MS in High Throughput Commercial Laboratories,Agilent Application Note,2004,5 989-1 585EN.