期刊文献+

DC电缆模型对电磁干扰仿真的影响 被引量:2

DC Cable Model Affection to Simulation of EMI
下载PDF
导出
摘要 本文提出了DC电缆传输线模型,利用Matlab/simulink对模型进行仿真,仿真表明DC电缆传输线参数对电磁干扰的仿真结果有影响:不加电缆模型时LISN的输出电压和传导干扰要比加电缆模型时大得多。这对于传导干扰研究中寄生参数的处理有一定的指导意义。 In this paper, the DC cable transmission line model is put forward. The model is simulated by using Matlab /simulink. The investigation shows that the DC cable transmission line parameter has an effect on EMI simulation: When you consider the cable model, the output voltage and conducted interference of LISN is much more higher than the output voltage without considering the cable model. But, the conducted interference is lower. This approach is very useful for future handling of parasitic capacitors in the study of conducted interference.
作者 李杰 单潮龙
出处 《船电技术》 2010年第4期14-19,共6页 Marine Electric & Electronic Engineering
关键词 传输线参数 电缆模型 电磁干扰 transmission line parameter cable model EMI
  • 相关文献

参考文献5

  • 1单潮龙,王向军等.电路[M].北京:国防工业出版社,2007.
  • 2Men Jin,Ma Weiming.A New Technique for Modeling and Analysis of Mixed-Mode Conducted EMI Noise[J].IEEE PESC'2004.
  • 3单潮龙,马伟明,王铁军,张俊洪.挂接三相逆变器的直流电网共模传导干扰研究[J].中国电机工程学报,2003,23(4):134-139. 被引量:25
  • 4Common Mode Filter Design Guide[J].Coilcraft,2002,Ducument:191-1-4.
  • 5Common Mode Filter Design Guide[J].Coilcraft,2002.Ducument:191-14.

二级参考文献7

  • 1Zhong E, Lipo T A. Improvements in EMC performance of inverterfed motor drives[J].IEEE Trans. on Indusitry Applications, 1995,31(6): 1247-1256.
  • 2Annette V J, Zhang Haoran, Wallace A K. An evaluation of mitigation techniques for beazing currents, EMI and overvoltages in ASD applications[J].IEEE Trans, on Industry Applications. 1998, 34(5):1113-1122.
  • 3Li Ran, Gokani S, Clare J, et al. Conducted electromagnetic emissions in induction motor drive systems Part Ⅰ:time-domain analysis and identification of dominant models[J].IEEE Trans.on Power Electronics, 1998, 13(4): 757-767.
  • 4Li Ran, Gokani S, Clare J, et al. Conducted electromagnetic emissions in induction motor drive systems Part Ⅱ: frequency domain models[J]. IEEE Trans. on Power Electronics, 1998, 13(4): 768-776.
  • 5Zhu Huibin. Analysis of conducted EMI emissions from PWM inverter based on empirical models and comparative experiments[C]. IEEE PESC'99.
  • 6Zhu Huibin. Modeling-based examination of conducted EMI emissions from hard- and soft-switching PWM inverters[J].IEEE Trans. on Industry Applications, 2001, 37(5): 1383-1393.
  • 7孟进,马伟明,刘德志,张磊.交流发电机整流系统传导电磁干扰的时域模型与仿真分析[J].中国电机工程学报,2002,22(6):75-79. 被引量:31

共引文献25

同被引文献13

引证文献2

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部