摘要 模拟电吹风正常使用、通电过热、正常使用后受火灾作用和通电过热后受火灾作用,获得在不同试验条件下的电吹风火灾残留物。用扫描电子显微镜对电吹风火灾残留物中的电热丝显微形貌进行观察。结果表明:在不同试验条件下,电热丝的显微形貌有明显的不同。因此,利用扫描电子显微镜观察电吹风电热丝的显微形貌,可以直观、快速地鉴别电吹风在火灾前所处的状态,为电吹风火灾事故的认定提供了一种新的技术方法。 Simulating four conditions of the hair dryer:normal used,electrical superheated,heated in fire after normal used,and heated in fire after electrical superheated,the fire residues of hair dryer were investigated. The microscopic appearances of heating wire were observed by scanning electron microscope.The result indicated that the microscopic appearances in different conditions were not same.Therefore,the state of the hair dryer before fire could be distinguished directly and quickly by observing the microscopic appearances of heating wires.This provided a new technical method for the recognition of fire accident.
作者 张辉 邹红
出处 《理化检验(物理分册)》 CAS 2010年第1期18-20,共3页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 电吹风 火灾残留物 显微形貌 鉴定技术 电热丝 hair dryer fire remains microscopic appearances appraisal technology heating wire
  • 相关文献

参考文献7

二级参考文献19

  • 1郝愫媛,高宏,刘海旭,门腾腾.扫描电镜/能谱仪在火灾原因技术鉴定中的应用[J].电子显微学报,2003,22(6):635-635. 被引量:5
  • 2张辉,邹红.热得快火灾危险性分析及火因鉴别方法的研究[J].武警学院学报,2000,16(3):52-55. 被引量:4
  • 3[1]胡汉起.金属凝固原理[M].北京:机械工业出版社,1988.
  • 4[2]家用电器原理及维修[M].北京:电子工业出版社,1994.
  • 5[3]小家电维修实例999[M].北京:电子工业出版社,1993.
  • 6王希庆等.电气火灾现场勘查与鉴定技术指南[M].沈阳:辽宁大学出版社,1996.
  • 7[美]J.I.戈尔茨坦..扫描电子显微技术与X射线显微分析[M]..北京:科学出版社,,1998....