摘要
介绍了TRT润滑油系统因双电源切换造成润滑油压力突然降低,发电机组紧急停机的原因,提出解决问题的方案,并且取得了很好的效果。
The causes of lubricating oil pressure of the TRT lubricating oil system suddenly dropping be- cause of dual power change-over to make the generating set emergently stop are presented. Solutions to this problem are advanced, with the adoption of which good results are achieved.
出处
《莱钢科技》
2010年第2期77-78,共2页
Laigang Science & Technology
关键词
润滑油系统
油压
双电源切换
lubricating oil system
oil pressure dropping
dual power switch-over