动态血糖监测系统的临床应用 被引量:3

CLINICAL APPLICATION OF CONTINUOUS BLOOD GLUCOSE MONITORING SYSTEM
下载PDF
导出
摘要 目的动态监测糖尿病(DM)患者血糖漂移的细节及波动趋势,为合理的治疗方案提供临床依据。方法采用动态血糖监测系统(CGMS)对20例DM患者进行连续72h的血糖监测。结果CGMS所测的血糖值与血浆血糖值及指端血糖值均呈显著正相关(r=0·93,r=0·91,(p值均<0·01)。按照动态血糖监测系统的结果调整治疗后,血糖控制至正常范围的比例由75·1%上升至92·0%,同时低血糖发生率由3·4%降至1·2%。结论动态血糖监测能较详细地显示DM患者血糖水平波动的特征,对拟定更为合理的治疗方案提供临床依据。 Objective To monitor the continuous blood glucose levels and their trends in DM(diabetes mel- litns). Methods The blood glucose levels.of 20 DM were detected with the CGMS(continuous glucose monitoring systems) for 72 h. Results The CGMS values in this study were signiilcanfly correlated with those of plasma glucose and capillary glucose ( r = 0. 89; r = 0. 91 ; both p 〈 0. 01 ). After adjusting the treatment protocol according to the results of CGMS, the rate of ideal blood glucose level increase from 75. 1% to 92. 0%, and the rate of hypoglycemia decrease from 3.4% to 1.2%. Condusion The CGMS provided information about the blood glucose excursions and trends in detail in DM, which are important to choose the optimal treatment protocol for the diabetes mellitus.
机构地区 揭阳市人民医院
出处 《现代医院》 2010年第4期78-79,共2页 Modern Hospitals
关键词 动态血糖监测 糖尿病 血糖波动 临床应用 Continuous glucose monitoring, Diabetes mellitns, Blood glucose level excursions, Application
  • 相关文献

参考文献8

二级参考文献20

  • 1喻明,周健,项坤三,李鸣,李青,周逸常.动态监测新诊断2型糖尿病患者的血糖水平[J].中华糖尿病杂志(1006-6187),2005,13(2):102-104. 被引量:87
  • 2喻明,吴松华,周健,李鸣,李青,张锋,朱敏,项坤三.新诊断2型糖尿病患者治疗前后血糖水平的动态变化[J].中国实用内科杂志,2005,25(10):881-883. 被引量:18
  • 3王宁玫.糖尿病运动疗法的护理干预[J].淮海医药,2006,24(2):150-151. 被引量:34
  • 4中国糖尿病协会.中国糖尿病防治指南[M].北京:北京大学医学出版社,2004:26.
  • 5薛耀明 沈洁.糖尿病的诊断与治疗[M].北京:人民军医出版社,2004.75.
  • 6Gross TM, Bode BW, Einhorn D, et al. Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol Ther,2000,2:49-56.
  • 7Mastrototaro J. The MiniMed continuous glucose monitoring system(CGMS). J Pediatr Endocriol Metab, 1999,12:751-758.
  • 8Bode BW, Gross TM, Thornton KR, et al. Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin. Diabetes Res Clin Pract, 1999,46:183-190.
  • 9Boyne MS, Silver DM, Kaplan J, et al. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes, 2003, 52:2790-2794.
  • 10Steil GM, Rebrin K, Mastrototaro J, et al. Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor. Diabetes Technol Ther,2003,5:27-31.

共引文献168

同被引文献27

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部