期刊文献+

给水泵变频改造应用实例 被引量:24

Case Study of Frequency Control Transformation of Feedwater Pump
下载PDF
导出
摘要 以汕头万丰热电厂给水泵变频改造为例,分析对给水泵进行交流变频改造的可行性;分别通过对单台给水泵及2台给水泵的变频改造情况分析了给水泵改造的经济性和节能效果,通过实际检验及测量改造后给水泵的节能效益,说明给水泵变频改造是电厂节能降耗的可行途径。 With the frequency control transformation of feedwater pump in Shantou Wanfeng Cogeneration Power Plant for example, the feasibility of conducting AC frequency control transformation of feedwater pump is analyzed. The economic efficiency and energy-saving effect of the transformation are analyzed according to the frequency control transformation results of single feed pump and two pumps respectively. The post-transformation test and measurement of energy-saving effect show that the frequency control transformation of feedwater pump is a feasible way for energy conservation and loss reduction in power plant.
出处 《广东电力》 2010年第3期76-79,共4页 Guangdong Electric Power
关键词 给水泵 变频 节能 feedwater pump frequency conversion energy conservation
  • 相关文献

参考文献1

  • 1吴民强.泵与风机节能[M].北京:水利电力出版社,1994.

共引文献4

同被引文献79

引证文献24

二级引证文献40