摘要
为了推广温湿度独立控制系统这一新型节能技术,介绍了潮湿地区(Ⅱ区)热泵驱动式溶液调湿机组的应用,对温湿度独立控制系统负荷计算、设备选型进行了详细的描述。温湿度独立控制系统相比常规空调系统节能30%且舒适性强。提出了溶液调湿机组在我国潮湿地区(Ⅱ区)有广泛的应用前景。并与传统空调系统相比较,论述了温湿度独立控制系统的优点及不足。
This paper describes the application of Heat pump - driven solution Conditioning Units in humid areas through practical projects ( Ⅱ district). Independent of temperature and humidity control system for load calculation, equipment selection were described in detail. Independent of temperature and humidity control system saves energy by 30% compared with conventional air- conditioning system. And compared with conventional air - conditioning system, it further discusses the advantages and disadvantages of temperature and humidity independent control system.
出处
《应用能源技术》
2010年第4期6-11,共6页
Applied Energy Technology
关键词
温湿度独立控制
高温冷源
末端装置
Independent of temperature and humidity
High- temperature cold source
End -device