摘要
国家863计划课题"MW级燃气轮机分布式冷电联供技术集成与示范研究"以佛山供电局季华路大院3栋大楼为依托,建成一个具有代表性的高效天然气冷电联供示范系统。以该示范系统为例,通过对分布式能源站的系统集成与优化运行控制策略的研究,提出了分布式能源站在经济工况下高效运行的方案。该方案可有效降低分布式能源站的投资和运行费用,大大促进分布式能源技术的应用和推广。
This paper introduces the distributed integrated cooling and power system of a demonstration project based on the Foshan Power Supply Bureau and discusses the principles of integration and operation optimization of the demonstration system. The controlling process of the integration and operation optimization is studied by taking the optimal economic mode as a case, which can provide a reference for highly-efficient operation of distributed energy stations at the economical working condition.
出处
《电力建设》
2010年第5期1-6,共6页
Electric Power Construction
基金
国家高技术研究发展计划(863计划)项目(2007AA05Z248)
关键词
分布式能源站
冷电联供
系统集成
优化运行
控制
策略
微型燃机
distributed energy station
combined cooling andpower
system integration
optimized operation
control strategy
micro turbine