期刊文献+

两起典型引风机变频器故障的分析 被引量:8

Analysis on Two Typical Faults of Frequency Converter of Induced Draft Fan
下载PDF
导出
摘要 高压变频器因具有节能、调速范围宽、调速精度高、动态响应快、运行效率高、操作方便等诸多优点,在电厂辅机中使用越来越广泛。虽然生产厂家在变频器制造过程中进行了可靠性设计,但由于变频器在长期使用过程中受温度、湿度、振动、灰尘、维护到位与否等因素的影响,或多或少会出现各种各样的异常及故障。针对两起较为典型的引风机变频器故障进行了分析,并对变频器的运行、维护等方面提出了建议。 With saving energy, wide speed range, high regulating precision, rapid dynamic response, high efficiency and operation easily, the high voltage frequency converter is more and more widely used in the auxiliary equipment of power plant. Although the frequency converter has been designed reliably in the manufacture process, it has also some various abnormities or faults caused by the long-term operation, maintenance, surrounding temperature, humidity, vibration, dust and so on. This paper analyzes the two typical faults of frequency converter of induced draft fan, and puts forward suggestions on operation and maintenance.
作者 陈善国
出处 《浙江电力》 2010年第4期44-46,共3页 Zhejiang Electric Power
关键词 变频器 引风机 故障 分析 frequency converter induced draft fan fault analysis