摘要
桥电五期锅炉自投运以来,锅炉送风机存在出口风压较低的问题,炉内燃烧处在严重缺风工况,影响机组的安全经济运行。1997年1月、5月桥头电厂先后两次请西安热工研究所有关专业人员进行现场测试;根据测试数据,组织专业人员查原因、定措施、出方案、抓落实,使送风机风压低的问题终于得到初步解决,基本满足锅炉燃烧风量的需要。
Since the normal service of the generating units in Qiaotou secondary power plant,the output pressure of the air feeder had been remained at low pressure,and the lack of air had been influenced the safe and economical operation of the units.To solve the measurements are taken.The paper describes the details.
出处
《青海电力》
1998年第3期40-42,共3页
Qinghai Electric Power
关键词
锅炉
送风机
风压
整治措施
电厂
Boiler,Air Feeder,Pressure,Cause,Analysis,Measurement