摘要 采用一种简易的MAP回收装置,研究了间歇运行条件下反应时间和曝气量对MAP法除磷效果的影响,确定出最佳反应时间为90 min,最佳曝气量为1.2 L/min,相应的除磷率可达98.26%,沉淀回收率为74.54%。当增加一个漏斗形隔板分离反应区和沉淀区并连续运行时,除磷率和沉淀回收率分别为92.11%和63.66%。当不投加镁盐和铵盐而仅调控实际污泥脱水滤液的pH值为9.8时,其连续运行的平均除磷率和MAP回收率分别可达95.16%和70%,运行性能比较稳定。 A simple magnesium ammonium phosphate(MAP) precipitation recovery device was designed and the effects of reaction times and aeration amounts on the phosphorus removal rate were studied under the intermittently operating congditions.The optimal reaction time was 90 minutes,the optimal aeration amounts was 1.2 L/min,the corresponding phosphorus removal rate and the precipitation recovery rate were 98.26% and 74.54% respectively.When a infundibuliform clapboard was added to separate the reaction region and the precipitation region,and the device was operated continuously.The phosphorus removal rate and the precipitation recovery rate were 92.11% and 63.66% respectively.Under the conditions that without adding the phosphate and magnesium and only adjusting the pH value of the sludge dewatering filtrate and operating continuously,the average phosphorus removal rate and the precipitation recovery rate were 95.16% and 70% respectively,and the opertating performance was stable.
出处 《环境工程学报》 CAS CSCD 北大核心 2010年第5期1047-1051,共5页 Chinese Journal of Environmental Engineering
基金 河南省教育厅自然科学研究计划项目(2008A610009)
关键词 磷酸铵镁 除磷 污泥脱水滤液 运行条件 magnesium ammonium phosphate(MAP) phosphorus removal sludge dewatering filtrate operating conditions
  • 相关文献

参考文献5

二级参考文献48

共引文献455

同被引文献45

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部