摘要
着重介绍了妈湾电厂HG1025/18.2-YM6型亚临界控制循环锅炉再热器管发生四次爆管的经过。分析了爆管原因,提出了今后改进的措施及建议。
The four explosions of reheater tubes on subcritical pressure controlled circulating boiler type HG1025/18. 2-YM6 in Mawan Power Plant are described. The explosion causes are analyzed and suggestions for improvement are set forward.
出处
《广东电力》
1998年第1期34-37,共4页
Guangdong Electric Power