期刊文献+

基于Matlab的双目CCD标定 被引量:1

Calibration of Binocular CCD Based on Matlab
下载PDF
导出
摘要 CCD标定作为图像采集处理的前端,直接影响到后继信息的处理.用Matlab软件实现CCD摄像机内外参数的标定,得出旋转矩阵和平移向量,并验证镜头畸变量对数据的影响.通过双目CCD交互式测距验证,测量结果误差小于0.3 mm,满足工业要求. As the basis of the image acquisition and processing, the calibration of CCD would affect the following studies on the image. Based on the Matlab, inner and outer parameters of CCD video camera were calibrated. Then the rotation matrix and the translation vector were calculated, the effect of the lens distortion on the data was verified. The verification of binocular CCD in the interactive range measurement shows that the error was less than 0.3 mm which satified the demand of industry.
出处 《上海工程技术大学学报》 CAS 2010年第1期51-55,共5页 Journal of Shanghai University of Engineering Science
基金 上海市科技攻关项目(08220511000) 上海工程技术大学研究生创新能力培养专项资金资助项目(09yjs29)
关键词 CCD标定 MATLAB软件 畸变 calibration of CCD Matlab software distortion
  • 相关文献

参考文献7

二级参考文献29

  • 1杨必武,郭晓松.摄像机镜头非线性畸变校正方法综述[J].中国图象图形学报(A辑),2005,10(3):269-274. 被引量:98
  • 2周国清,袁保宗,唐晓芳.论CCD相机标定的内、外因素:畸变模型与信噪比[J].电子学报,1996,24(11):12-17. 被引量:17
  • 3Ma S,IEEE Trans Robotics Automation,1996年,12卷,114页
  • 4Shashua A,IEEE Trans PAMI,1995年,17卷,779页
  • 5Wei G,IEEE Trans PAMI,1994年,16卷,5期
  • 6Luong Q T,INRIA Research Report,1993年,1894期
  • 7Weng J,IEEE Trans PAMI,1992年,14卷,10期,965页
  • 8Wei G,Proc.CVPR’91.,1991年,133页
  • 9Luh J Y,IEEE Trans PAMI,1985年,7卷,1期
  • 10Hall E L,Proc. IEEE Workshop on Industrial Application of Machine Vision,1982年