实验动物手术室使用臭氧和紫外线灭菌的效果观察 被引量:9

To Observe the Effects of Sterilization Using Ozone and Ultraviolet Light in the Animal Surgery Laboratory
下载PDF
导出
摘要 目的观察以肝、心、肾等器官移植为主的医学实验动物手术室,使用臭氧和紫外线的物理学方法灭菌的效果。方法在实验室运转后,用物理的臭氧和紫外灭菌与化学的2%戊二醛灭菌方法进行比较,用平皿菌落记数和物品表面微生物检测,重复消毒灭菌和检测各3 d,观测消毒灭菌效果。结果臭氧的泄漏不多,易于隔离和应用。两种方法的平皿菌落记数和物品表面微生物检测均达标。结论臭氧和紫外线物理灭菌方法在完成消毒后无残留物质,可进入缝隙,在实验动物手术室等存放大量仪器物品的实验室,用物理方法替代化学方法值得提倡。 Objective To evaluate the efficacy,the physical disinfection method of ozone and UV was studied in the animal surgery laboratory,in which the main direction is organ transplantation of animal liver,heart and kidney.Methods In an animal clean room,where there is a day-night cycle of operation and rest,the efficacy of disinfection and sterilization was evaluated.Using culture utensils and surface microbe inspections,we compared the physical disinfection methods of ozone and UV to the chemical method of 2% Glutaral.Both sterilization processes were conducted during the night.Results Both methods achieved a normal level of sterilization after three times.However,the ozone is easy to isolate,safe to use and does not require washing.Conclusion Both Ozone and UV are physical factors.They are a good alternative to the chemical sterilization methods,as there are no waste products Also ozone is able to thoroughly permeate all parts of the equipment,including the hard to reach interior.As the needs of organ transplantation research increase,large numbers of equipment and materials need to be kept in the lab for long periods of time.Therefore it is important to establish an effective disinfection method.Our results suggest that at the correct dosage of ozone and UV,we can achieve good sterilization results in the animal surgery laboratory.
出处 《实验动物科学》 2010年第2期35-37,共3页 Laboratory Animal Science
关键词 实验动物 手术室 物理灭菌(臭氧) 化学灭菌 Experimental animal Surgery laboratory Physical sterilization(ozone) Chemical sterilization
  • 相关文献

参考文献4

二级参考文献25

  • 1Roubin MR, Pharmnond JS, Zanelli F, et al. Application of laser scanning cytometry followed by epifluorescent and differential interference contrast microscopy for the detection and enumeration of Cryptosporidium and Giardia in raw and potable waters[J] . Journal of Applied Microbiology 2002; 93:599.
  • 2Mansfield I.,P, Fomythe SJ. Immunomagnetic Separation as an alternative to enrichment broths for salmonella detection[J] . Appl Microbiol ,1993; 16:122.
  • 3Stannard C J, Petitt SB, Skinner FA. Rapid Microbiological Methods for foods,Beverages and Pharmaceuticals[M]. Oxford: Blackwell Sci Publ, 1989:33 -71.
  • 4Stewart GSAB. In vivo bioluminescence: new potentials for microbiology[J] . Letters in Applied Microbiology. 1990 ; 10 : 1.
  • 5Nijskens JJ, Baakman R. Performance indicators of hygiene during animal transportion: results of a large scale monitoring of trucks with ATP - bioluminescent techniques [J] . Tijdsehr Diergeneeskd, 2001 ; 126( 14-15 ) : 488.
  • 6Baumgart J. Possibilities and limits of modem rapid procedures for process control of cleaning and disinfection methods[J] . Zentralbl Hyg Umweltmed. 1996 ; 199(2-4) : 366.
  • 7Cowan HE, Falkindam J. A luciferase - based method for assessing chlorine - susceptibility of Mycobacterium avium [J] . J Microbiol Methods. 2001 ; 46 (3): 209.
  • 8Jefferson RA, Burgess SM, Hirsh D. β -glucuronidase fromEseherichia coil as a gene fusion marker[J] . Proceedings of the National Aeaclemy of Sciences USA. 1986; 86:8447.
  • 9Caruso G, Crisafi E, Maneuso M. Development of an enzyme assay for rapid assessment of Escherichia cob in seawaters [J] .Journal of Applied Microbiology. 2002 ; 93:548.
  • 10Tsomlexoglou E, Daulagula K_P, C, ooday GW, et al. Moleculardetection and β - glucuronidase expression of gus - marked Bacillus subfilis L -form bacteria in developing Chinese cabbage seedlings[J] . Journal of Applied Microbiology. 2003 ; 95:218.

共引文献3

同被引文献92

引证文献9

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部