摘要 目的评价ABXMICROS60(以下简称ABX)与BC-3000plus(以下简称BC-3000)2台产地不同的血液分析仪的主要性能,观察2种血液分析仪测定WBC、RBC、HGB、HCT、PLT的结果是否一致。方法所检测的新鲜全血为常规标本和质控液,在ABX与BC-3000血液分析仪组成的检测系统上测定,进行仪器的性能评价对比。结果2种仪器检测的结果比较为WBCt=0.6686<t0.05(19),P>0.05;RBCt=0.0304<t0.05(19),P>0.05;HGBt=0.5446<t0.05(19),P>0.05;HCTt=0.4986<t0.05(19),P>0.05;PLTt=1.4330<t0.05(19),P>0.05。差异均无统计学意义。结论检测ABX和BC-3000血液分析仪性能良好,均能满足血液常规分析的一般要求。2台仪器的结果差异无统计学意义。 [Objective]To evaluate the main performance of ABX MICROS 60 hematology analyzer(ABX)and BC-3000 plus hematology analyzer(BC-3000),observe the difference in detection results of WBC,RBC,HGB,HCT and PLT between two hematology analyzers.[Methods]The blood routine samples and quality control samples were tested by the detection system composed of ABX and BC-3000 hematology analyzer.The performance of two instruments were evaluated and compared.[Results]No significant difference was found in the detection results between two hematology analyzers,which WBC was t=0.6686t0.05(19),P0.05;RBC was t=0.0304t0.05(19),P0.05;HGB was t=0.5446t0.05(19),P0.05;HCT was t=0.4986t0.05(19),P0.05;PLT was t=1.4330t0.05(19),P0.05.[Conclusion]ABX MICROS 60 hematology analyzer and BC-3000 hematology analyzer show the good performance and can achieve the clinical demand of hematological analysis.There was no significant difference in detection results between two hematology analyzers.
作者 朱玉玮
机构地区 天津市第三医院
出处 《职业与健康》 CAS 2010年第9期996-997,共2页 Occupation and Health
关键词 血细胞分析仪 BC-3000 ABX RBC WBC HGB HCT PLT Hematology analyzer BC-3000 ABX RBC WBC HGB HCT PLT
  • 相关文献

参考文献1

二级参考文献1

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部