期刊文献+

脑电双频谱指数和正中神经体感诱发电位监测窥喉插管应激反应的比较

Comparison of accuracy of bispectral index and median nerve somatosensory evoked potential for assass. ment of stress during laryngoscopy and tracheal intubation
原文传递
导出
摘要 目的比较脑电双频谱指数和正中神经体感诱发电位监测异丙酚诱导下窥喉插管所致应激反应的可行性和准确性。方法选择16-40岁ASAI-Ⅲ级无神经精神系流疾病患者15例,异丙酚和司可林麻醉后行气管插管,记录插管前、中、后的MnSSEP、BIS、SBP、DBP、HR。结果插管即刻MnS,SEP的P15N20、N20P25波幅增高,插管后N20P25恢复,P15N20仍增高,其余波幅无改变。插管前后MnSSEP各波潜伏期均无改变,并BIS无明显改变。插管即刻和插管后SBP、DBP较插管前增高而HR无明显改变。结论正中神经体感诱发电位的N20P25适于反映气管插管对神经系统的影响,P15N20适于反映气管插管对心血管系统的影响,BIS值不能反映窥喉插管的应激反应。 Objective To comparison of accuracy of bispectral index and median nerve somatosensory evoked potential for assassment of stress during laryngoscopy and tracheal intubation. Methods Fifteen ASA Ⅰ - Ⅱ patients aged 16-40 yrs undergoing elective surgery under general anesthesia. Anesthesia was induced with TCI propofol. After the target effect-site concentration of propoful reach 6 μg/ml and maintained for two mi- nutes,intubation was facilitated. Results There were no changes in all latencies of MnSSEP, BIS and HR. Dur- ing intubation, amplitudes of N20P25 increased, and after that they reinstated. SBP, DBP and P15N20 increased during and after intubation. Conclusion N20P25 is suitable to reflect the effects of intubation to nerve system. P15N20 is suitable to reflect the effects of intubation to cardiovascular system. BIS can not reflect the stress of intubation.
出处 《中国临床实用医学》 2010年第5期17-18,共2页 China Clinical Practical Medicine
关键词 窥喉插管 诱发电位 躯体感觉 应激反应 脑电描记术 Laryngoscopy and Tracheal intubation Evoked potential Somatosensory Stress reaction Electroeneephalography
  • 相关文献

参考文献11

  • 1Zhenilo VM, Beliaevskii AD, Bychkov AA, Zelenina TA. Computer analysis of components of general anesthesia. Anesteziol Reanimatol,2001,3 :6-8.
  • 2杨涛,钟亮.异丙酚和异氟醚在体感通路上的作用部位[J].中华麻醉学杂志,2003,23(3):178-181. 被引量:4
  • 3Struys MM, Jensen EW, Smith W, et al. Performance of the ARX-derived auditory evoked potential index as an indicator of anesthetic depth:a comparison with bispeetral index and hemodynamie measures during propofol administration. Anesthesiology, 2002, 96 : 803-816.
  • 4吕艳霞,柳顺锁,刘志双,孟庆云,李会春.卡托普利对全麻诱导气管内插管时循环反应的作用[J].中华麻醉学杂志,2003,23(7):492-495. 被引量:2
  • 5Leslie K,Sessler DI,Smith WD,et al. Prediction of movement during propofol/nitrous oxide anesthesia. Anesthesiology 1996,84:52-63.
  • 6Hall JD ,Lockwood GG. Bispectral index:comparison of two montages. Br J Anaesth, 1998,80:342-344.
  • 7M. Doi,R. J. Gajraj ,H. Mantzaridis,et al. Prediction of movement at laryngeal mask airway insertion:comparison of auditory evoked potential index, bispectral index, spectral edge frequency and median frequency. British Journal of Anaesthesia, 1999,82 (2) :203 -207.
  • 8Kear LA, Rosow C,Zaslvsky A, et al. Bispectral analysis of electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis. Anesthesiology, 1998,88 : 25-34.
  • 9Katoh T, Suzuki A, Ikeda K. Electrooncephalographie derivatives as a tool for predicting the depth of sedation and anesthesia induced by sevoflurane. Anesthesiology 1998,88:642-650.
  • 10Pry-Roberts C. Anesthesia: A practical or impractical construct Br J Anesth, 1987,59 : 1341-1345.

二级参考文献15

共引文献4