Gas leakage monitoring with scanned-wavelength direct absorption spectroscopy 被引量:1

Gas leakage monitoring with scanned-wavelength direct absorption spectroscopy
原文传递
导出
摘要 A natural gas leakage detector based on scanned-wavelength direct absorption spectroscopy is described. The sensor employs a multi-channel scanned-wavelength direct absorption strategy.It has the potential to simultaneously monitor methane and hydrogen sulfide in open path environment.Traditionally,scanned-wavelength direct absorption spectroscopy is the technique choice for natural gas leakage applications because of its simplicity,accuracy,and stability.We perform the gas sensor using direct-absorption wavelength scans with isolated features at 1-kHz repetition rate and the center wavelength is stabilized at the center of the 2v_3 band R(3) line of methane(1.65μm) and the(v_1+v_2+v_3) combination band of hydrogen sulfide(1.57μm),respectively.The influence of light intensity fluctuations can be eliminated by using scanned-wavelength direct absorption spectroscopy.Because of the fast wavelength scanning,the sensor has a response time of less than 0.1 s.The sensor can be configured to sense leakages in path-integrated concentrations of,for example,100-ppm·m hydrogen sulfide and 10-ppm·m methane. A natural gas leakage detector based on scanned-wavelength direct absorption spectroscopy is described. The sensor employs a multi-channel scanned-wavelength direct absorption strategy.It has the potential to simultaneously monitor methane and hydrogen sulfide in open path environment.Traditionally,scanned-wavelength direct absorption spectroscopy is the technique choice for natural gas leakage applications because of its simplicity,accuracy,and stability.We perform the gas sensor using direct-absorption wavelength scans with isolated features at 1-kHz repetition rate and the center wavelength is stabilized at the center of the 2v_3 band R(3) line of methane(1.65μm) and the(v_1+v_2+v_3) combination band of hydrogen sulfide(1.57μm),respectively.The influence of light intensity fluctuations can be eliminated by using scanned-wavelength direct absorption spectroscopy.Because of the fast wavelength scanning,the sensor has a response time of less than 0.1 s.The sensor can be configured to sense leakages in path-integrated concentrations of,for example,100-ppm·m hydrogen sulfide and 10-ppm·m methane.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第5期443-446,共4页 中国光学快报(英文版)
基金 supported by the importantly directional project of Knowledge Innovation Program of Chinese Academy of Sciences(No.KGCX2-YW-121-1) the National Defense Pre-Research Fund of Chinese Academy of Sciences(No.CXJJ-09-M38).
关键词 Gas absorption? ?Gas fuel purification? ?Hydrogen? ?Methane? ?Natural gas? ?Sensors? ?Wavelength Gas absorption   Gas fuel purification   Hydrogen   Methane   Natural gas   Sensors   Wavelength
  • 相关文献

参考文献8

  • 1R. Claps, F. V. Englich, D. P. Leleux, D. Richter, F. K. Tittel, and R. F. Curl, Appl. Opt. 40, 4387 (2001).
  • 2X. Zhou, J. B. Je?ries, and R. K. Hanson, Appl. Phys. B 81, 711 (2005).
  • 3X. Zhu and D. T. Cassidy, Appl. Opt. 34, 8303 (1995).
  • 4D. P. Leleux, R. Claps, W. Chen, F. K. Tittel, and T. L. Harman, Appl. Phys. B 74, 85 (2002).
  • 5F. D'Amato, P. Mazzinghi, and F. Castagnoli, Appl. Phys. B 75, 195 (2002).
  • 6R. T. Wainner, B. D. Green, M. G. Allen, M. A. White, J. Stafford-Evans, and R. Naper, Appl. Phys. B 75, 249(2002).
  • 7T. Iseki, Environmental Geology 46, 1064 (2004).
  • 8H. Xia, W. Liu, Y. Zhang, R. Kan, M. Wang, Y. He, Y. Cui, J. Ruan, and H. Geng, Chin. Opt. Lett. 6, 437(2008).

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部