期刊文献+

鲁米诺-高锰酸钾流动注射化学发光体系测定头孢呋辛钠 被引量:2

Flow-Injection Chemiluminescence Determination of Cefuroxime Sodium Using Luminol-Potassium Permanganate System
下载PDF
导出
摘要 在碱性介质中,鲁米诺与高锰酸钾反应产生化学发光,头孢呋辛钠能增强其化学发光强度,据此,建立了流动注射化学发光测定头孢呋辛钠的新方法。在最佳实验条件下,相对发光强度与头孢呋辛钠的质量浓度在2.0×10-7—8.0×10-5g/mL范围内,呈良好的线性关系,方法的检出限为3.0×10-8g/mL;对8.0×10-6g/mL头孢呋辛钠进行11次平行测定,相对标准偏差为1.1%。该方法用于合成样品及尿样的测定,结果满意。 A new chemiluminescence method coupled with the flow injection technique for determination of cefuroxime sodium is developed.It is based on the enhancement of chemiluminescence intensity for cefuroxime sodium on the chemiluminescence reaction of luminol with potassium permanganate in an alkaline medium.Under the optimum conditions,the linear range for cefuroxime sodium is 2.0×10-7— 8.0×10-5g/mL and the limit of detection is 3.0×10-8g/mL.The relative standard deviation(n=11) is 1.1% for 8.0×10-6g/mL cefuroxime sodium.The proposed method has been applied to the determination of cefuroxime sodium in synthetical samples and urine samples with satisfactory results.
机构地区 郑州大学化学系
出处 《光谱实验室》 CAS CSCD 北大核心 2010年第3期1195-1199,共5页 Chinese Journal of Spectroscopy Laboratory
基金 国家自然科学基金(No.J0830412)
关键词 化学发光 流动注射 头孢呋辛钠 鲁米诺 高锰酸钾 Chemiluminescence Flow Injection Cefuroxime Sodium Luminol Potassium Permanganate
  • 相关文献

参考文献9

二级参考文献22

  • 1郭丹,陈娜娜,杨西晓,晏媛,侯连兵.注射用头孢呋辛钠的HPCE测定[J].中国医药工业杂志,2004,35(8):480-481. 被引量:5
  • 2章可铭,王临润.紫外分光光度法测定头孢呋辛钠的含量[J].现代应用药学,1996,13(3):41-42. 被引量:5
  • 3匿名著者,1990年
  • 4.中华人民共和国药典二部2000年版[S].[S].中华人民共和国药典委员会编,2000.177.
  • 5中华人民共和国国家药典委员会.中国药典[s].二部[M].北京:化学工业出版社,2000.附录86.
  • 6Markovic S, Banjanin V. UV spectrophotometric determination of acemetacin [ J]. Arh Farm, 1986,36 (3) :113 -117.
  • 7SchollnhammerG, Dell HD, Doersing K, et al.Quantitative determination of acemetacin and metabocite indometacin in blood and plasma by column liquid chromatography [J]. J Chromatogr, 1986,375(2) :331- 338.
  • 8Hirai T, Matsumoto S, Kishi I. Simultaneous analysis of several non-steroidal anti-inflammatory drugs in human urine by high-performance liquid chromatography with normal solid-phase extraction [ J ]. J Chromatogr B,1997,692(2) :375 -388.
  • 9Escuder-Gilabert L, Martin-Biosca Y, Sagrado S, et al.Quality control of pharmaceuticals containing nonsteroidal anti-inflammatory drugs by micellar liquid chromatography [ J ]. Chromatographia, 2002,55 ( 5 -6): 283 - 288.
  • 10Lopez PJ, Arcos J, et al. Electrochemical behavior of acemetacin [ J ]. J Pharm Biomed Anal, 1988,6 (6 - 8 ):963 - 968.

共引文献22

同被引文献118

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部